S E L E C T I O N
COAXIAL TYPE GWR PROBE
G U I D E
TWIN ROD/CABLE TYPE GWR PROBE
SINGLE ROD/CABLE TYPE
signal propagation
signal propagation
signal propagation
end view
end view
Application
Dielectric
Limit
Temperature
Limits
Pressure
Vacuum
Œ
Applications
Overfill Safe
Foam

GWR
Probe
Coaxial GWR Probes:
Maximum Viscosity 500 cP (I.D.
3
4
") – 1500 cP (I.D. 1
3
4
")
Level
High Temp./High Pressure
Level/Interface
ε
r
1.4–100
Ž
ε
r
1.4–100
ε
r
1.9–100
ε
r
1.9–100
ε
r
1.9–100
ε
r
1.9–100
ε
r
1.9–100
ε
r
1.9–100
ε
r
4–100
ε
r
10–100
ε
r
1.4–100
-40° to +400° F max 1015 psig
(-40° to +200° C)
(70 bar)
-321° to 800° F max 6250 psig
(-196° to +430° C)
(430 bar)
up to +650° F
(up to +345° C)
max 2250 psig
(155 bar)
Yes
Full
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
7xR
7xM
7xD
7xL
7xS
7xT
7xN
Saturated Steam
Interface
-40° to +400° F max 1015 psig
(-40° to +200° C)
(70 bar)
Twin Rod/Cable GWR Probes:
Maximum Viscosity 1500 cP
-40° to +400° F max 1000 psig
(-40° to +200° C)
(70 bar)
-40° to +400° F max 1000 psig
(-40° to +200° C)
(70 bar)
Ambient
Atmospheric
Yes
Yes
Yes
No
No
No
Yes
No
n/a
7xB
7x7
7x5
Liquids – Rod
Liquids – Cable
(level/interface)
Solids – Cable
Single Rod/Cable GWR Probes:
Maximum Viscosity 10,000 cP
-40° to +300° F max 1000 psig
(-40° to +150° C)
(70 bar)
-40° to +300° F max 1000 psig
(-40° to +150° C)
(70 bar)
Ambient
Atmospheric
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
n/a
Yes
7xF
7x1
7x2
7xJ
Liquids – Rod

Liquids – Cable

Solids – Cable
High Temp./
High Pressure

Œ
Each Eclipse probe can be used for vacuum service (negative pressure) but only the Borosilicate

Eclipse is ideally suited to be used on foaming applications but in specific conditions where dense
GWR probes (7xD/7xL) are suited for full vacuum conditions (Helium leak < 10
-8
cc/s @ 1 bar abs.)
foam can enter in the stilling well, coaxial GWR probes are not recommended.
-40° to +600° F max 3002 psig
(-40° to +315° C)
(207 bar)
Ž
Depends on the spacer material. See model selection 7xD/7xL GWR probe.

For media with
ε
r 1.9 to 10, GWR probe must be mounted between 3" and 6" (75 and 150 mm)