27C010T
1 Megabit (128K x 8-Bit) - OTP EPROM
TABLE 4. 27C010T RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
MIN
MAX
UNITS
Supply Voltage
Input Voltage
VCC
VIL
4.5
-0.31
2.2
--
5.5
0.8
VCC +12
V
V
VIH
ΘJC
TA
Thermal Impedance
1.27
°C/W
°C
Operating Temperature Range
-55
+125
1. VIL min = -1.0V for pulse width < 50 ns.
2. VIH max = VCC + 1.5V for pulse width < 20 ns.
1
TABLE 5. 27C010T CAPACITANCE
PARAMETER
SYMBOL
MIN
MAX
UNIT
Input Capacitance
Output Capacitance
CIN
--
--
10
15
pF
pF
COUT
1. Guaranteed by design.
TABLE 6. 27C010T DC ELECTRICAL CHARACTERISTICS FOR READ OPERATION
(VCC = 5V ± 10%, VPP = VSS, TA = -55 TO +125 °C, UNLESS OTHERWISE SPECIFIED)
SUB
GROUPS
PARAMETER
SYMBOL
TEST CONDITION
MIN
TYP
MIN
UNIT
Input Leakage Current
Output Leakage Current
Standby VCC Current
Operating VCC Current
ILI
VIN = 5.5V
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
--
--
--
--
--
--
--
--
1
2
2
µA
µA
mA
mA
ILO
VOUT = 5.5V/0.45V
CE = VIH
ISB
--
1
ICC1
ICC2
ICC3
IPP1
VIH
VIL
IOUT = 0 mA, CE = VIL
IOUT = 0 mA, f = 5 MHz
IOUT = 0 mA, f = 10 MHz
VPP = 5.5V
--
30
30
50
20
--
--
--
V
PP Current
--
µA
V
Input Voltage
2.2
--
--
--
--
--
0.8
--
Output Voltage
VOH
VOL
IOH = -400 µA
IOL = 2.1 mA
2.4
--
V
0.45
12.12.01 Rev 2
All data sheets are subject to change without notice
3
©2001 Maxwell Technologies