MX29F080
AC CHARACTERISTICS TA = 0oC to 70oC, VCC = 5V ±10%
29F080-70
29F080-90
29F080-12
SYMBOL PARAMETER
MIN.
MAX.
MIN.
50
90
45
20
20
0
MAX.
MIN.
50
120
50
20
20
0
MAX. UNIT
tOES
tCWC
tCEP
tCEPH1
tCEPH2
tAS
OE setup time
50
70
35
20
20
0
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Command programming cycle
WE programming pulse width
WE programming pluse width High
WE programming pluse width High
Address setup time
tAH
Address hold time
45
30
0
45
45
0
50
50
0
tDS
Data setup time
tDH
Data hold time
tCESC
tDF
CE setup time before command write
Output disable time (Note 1)
Total erase time in auto chip erase
0
0
0
20
30
30
ns
s
tAETC
tAETB
tAVT
8(TYP.)
64
8(TYP.)
64
8(TYP.)
64
Total erase time in auto sector erase 1.3(TYP.)
Total programming time in auto verify 7(TYP.)
10.4
210
1.3(TYP.)
10.4
210
1(TYP.)
10.4
210
s
7(TYP.)
7(TYP.)
us
us
ns
ns
us
us
us
ms
tBAL
Sector address load time
CE Hold Time
80
0
80
0
80
0
tCH
tCS
CE setup to WE going low
Voltge Transition Time
0
0
0
tVLHT
tOESP
tWPP1
tWPP2
4
4
4
OE Setup Time to WE Active
Write pulse width for sector protect
4
4
4
10
10
12
10
12
Write pulse width for sector unprotect 12
NOTES:
1. tDF defined as the time at which the output achieves the open circuit condition and data is no longer driven.
P/N:PM0579
REV. 1.4, JAN. 16, 2002
16