MLX16303
Bi-directional Remote Sensor Unit Interface
4. MLX16303 electrical specifications
Tamb = -40 to 85° and Tj = -40 to 150°C
C
VS operation supply voltage range 4.9V to 7.7 V
(Remote unit connection OUTx to RETx pin)
or
VS operation supply voltage range 6.0V to 7.7 V
(Remote unit connection OUTx to GND pin)
VP programming voltage range 9.6V to 16.2V
All voltages are referenced to the GND pins potential if no other voltage potential is mentioned
Parameter
Symbol
Conditions
Min
Max
Units
VS (sidesat connection OUTx to RETx pin)
Supply Voltage Range
Supply current OUT0 and OUT1 switched off
Supply current OUT0 and OUT1 switched on
At 6.0V ≤ VS ≤ 7.7V, IOUT0 = IOUT1 = 45 mA
Supply current OUT0 and OUT1 switched on
At 4.9V ≤ VS ≤ 6.0V, IOUT0 = IOUT1 = 35 mA
Ivson
80
mA
Vvs
Ivsoff
Ivson
4.9
7.7
6
100
V
mA
mA
VS (sidesat connection OUTx to GND pin)
Supply Voltage Range
Supply current OUT0 and OUT1 switched off
Supply current OUT0 and OUT1 switched on
IOUT0 = IOUT1 = 45 mA
Vvs
Ivoff
Ivson
6.0
7.7
6
100
V
mA
mA
VDD
VDD Voltage Range
VDD Supply current
Vvdd
Ivdd
4.9
5.1
1.5
V
mA
VP threshold
Threshold Voltage for entering in Programming Mode Vvp
(limits are relative to Vdd, rising edge)
Hysteresis of threshold Voltage for entering in
Programming Mode (limits are relative to Vdd)
@25°C
@25°C
9.4
0.05
9.6
0.15
V
V
VP
Programming Voltage Range
Vvp
9.6
16.2
V
3901016303
Rev. 004
Page 6 of 20
Data Sheet
Jun/04