MLX90807
Relative Integrated Pressure Sensor
3 Absolute Maximum Ratings
Symb
ol
Supply Voltage (overvoltage)
V
DD
Supply Voltage (operating)
V
DD
Supply Current, I
DD
with V
DD
= 16 V
I
DD
Output Voltage, V
out
V
out
Supply current with output shorted to 0V .. 16V I
DD
Supply Current limit, reverse polarity
I
DD
Programming Temperature Range (ZAP cells) T
P
Operating Temperature Range
T
A
Storage Temperature Range
T
S
ESD Sensitivity (AEC Q100 002)
Table 1: Absolute maximum ratings
Parameter
Min Value
-14
4.5
-0.5
Max Value
16
5.5
25
16
100
160
100
140
150
2
Units
V
V
mA
V
mA
mA
°C
°C
°C
kV
-20
-40
- 50
-2
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-
rated conditions for extended periods may affect device reliability.
4 General Electrical Specifications
DC Operating Parameters T
A
= -40 C to 140 C, V
DD
= 5V (unless otherwise specified)
Parameter
Symbol
Supply Voltage
V
dd
Supply Current
I
dd
Output Current Capability
I
out
output @ low pressure
V
out
output @ full scale pressure V
out
Low Clamping level
V
out
High Clamping level
V
out
Linearity error
V
out
Ratiometricity error
V
out
Programming Supply
V
cc prog
Zapping Supply
V
zap
Zapping Temperature
T
zap
Lifetime
Power-up time
Power-up time
Response time 0% / 63%
T
rp
Response time 10% / 90% T
rp 10 – 90
Stabilization time
T
s
Pressure accuracy
Table 2: Electrical specifications
Test Conditions
Operating
V
dd
= 5 V ± 10% , excluding output current
V
dd
= 5 V
V
dd
= 5 V
V
dd
= 5 V
Min Typ
4.5
5
4
7
1
0.46 0.5
4.46 4.5
6.5
91
-0.5
-0.3
10
15.5
- 20
15
3.5
5
1
1.5
3
Max Units
5.5
V
10
mA
mA
0.54
V
4.54
V
8.5 % V
od
93.5 % V
od
0.5 % V
od
0.3 % V
od
10.5
V
16
V
o
C
100
Year
ms
ms
ms
ms
ms
1
% FS
o
o
T = 0 C … 85 C
o
o
T < 0 C or T > 85 C
o
o
3901090807
Rev 003
Page 3 of 8
Data Sheet
Feb 08