Relative Integrated Pressure Sensor  
7 Unique Features  
Diagnostic Limits  
Diagnostic of broken sensor: The output will be forced to ground (or a very low level) when the sensor  
membrane breaks.  
Diagnostic of broken wires: The output will be forced to ground (or a very low level) when the supply wire  
breaks, even when a pull-up is still connected to the output pin.  
The output will be forced to the supply voltage (or a very high level) when the ground wire breaks, even when  
a pull-down is still connected to the output pin.  
Output Protection  
The output is protected against short-circuits at either battery terminals. The output can handle voltages  
between -0.5V and 16V (independent of supply voltage).  
Memlock Function  
The memory consists of ZAP cells. When all calibration parameters are programmed, the chip can be locked.  
This to avoid unwanted that data be written into the memory cells.  
Once the chip is locked in a normal application, we can not read the zap contents and it is not possible to  
unlock afterwards, unless the MOW pin is used. This can be done by apply a supply between 2.5V and 3.5V  
on the MOW pin, then we can read back the content of the memory cells and zap another cell if necessary.  
Clamping Levels  
The user can enable the clamping of the output to ensure that the output can not enter the fault band in  
normal application.  
8 Application Information  
47nF  
47nF  
Very few off-chip components are needed (only 2 decoupling capacitors, not higher than 100 nF).  
Only 3 pins are used (Vdd, Vss, Out), see pad layout drawing in paragraph 9.  
Calibration and Programming is made through the OUT pin.  