WRB-YD -30W
Series(2
.
16)
TEMPERATURE CHARACTERISTICS
Parameter
Output voltage accuracy
Over load protection
Output Short Circuit
Load regulation
Trim
Temperature drift (Vout)
Line regulation
Ripple&Noise
Transient recovery time
Transient peak deviation
3.3V
5V
Over voltage protection
12V
15V
24V
Input voltage from low to high
Tested under 20MHz brand
25% load change
±2
3.63
5.5
13.2
16.5
26.4
50
±0.2
75
200
±3
TYPICAL CHARACTERISTICS
Typ.
±1
130
Conditions
Refer to recommended circuit
Input voltage range
Input voltage range
From 10% to 100% load
Min.
120
Max.
±3
150
Units
%
%
Temperature Derating Graph
Hiccup,automatics recovery
±0.5
±10%V0
0.02
±0.5
150
300
±5
4.29
6.5
15.6
19.5
31.2
±1
%
VDC
%/℃
%
mV
us
%
VDC
VDC
VDC
VDC
VDC
RECOMMENDED CIRCUIT
Output Graph
Note:
1. All specifications are measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
2. The CTRL control pin voltage is referenced to GND.
3. Typical efficiency value at nominal input voltage and full load.
4. Capacitor MAX load tested at nominal input voltage and constant resistive load.
5. Refer to the diagram of Output Voltage trim up/down for trim applications.
6. The products cannot be used in parallel and in plug and play.
In order to abtain better performance for the DC/DC
models.it’s recommended that use input and output
filters as Fig.1 shown.
L:12uH
C:100uF/100V
Case material
&
EFFICIENCY CURVE
DERATING
DERATING&
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load
no less than 10% load
the actual
load.If
load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Curve of Efficiency VS input Voltage WRB2424YD-30W
OUTPUT VOLTAGE TRIM
Output Graph
Curve of Efficiency VS output load WRB2424YD-30W
No parallel connection or plug and play
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2
2
of 3