欢迎访问ic37.com |
会员登录 免费注册
发布采购

M5M4V4S40CTP-12 参数 Datasheet PDF下载

M5M4V4S40CTP-12图片预览
型号: M5M4V4S40CTP-12
PDF下载: 下载PDF文件 查看货源
内容描述: 4M ( 2 - X银行131072 -字×16位)同步DRAM [4M (2-BANK x 131072-WORD x 16-BIT) Synchronous DRAM]
分类和应用: 存储内存集成电路光电二极管动态存储器时钟
文件页数/大小: 45 页 / 1459 K
品牌: MITSUBISHI [ Mitsubishi Group ]
 浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第6页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第7页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第8页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第9页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第11页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第12页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第13页浏览型号M5M4V4S40CTP-12的Datasheet PDF文件第14页  
MITSUBISHI LSIs  
SDRAM (Rev. 0.3)  
M5M4V4S40CTP-12, -15  
Feb ‘97 Preliminary  
4M (2-BANK x 131072-WORD x 16-BIT) Synchronous DRAM  
FUNCTION TRUTH TABLE for CKE  
CKE CKE  
Current State  
/CS /RAS /CAS /WE Add  
Action  
n-1  
H
L
n
X
H
H
H
H
H
L
X
H
L
X
X
H
H
H
L
X
X
H
H
L
X
X
H
L
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
INVALID  
SELF-  
REFRESH*1  
Exit Self-Refresh (Idle after tRC)  
Exit Self-Refresh (Idle after tRC)  
ILLEGAL  
L
L
L
L
L
X
X
X
X
X
X
X
H
X
H
L
ILLEGAL  
L
L
X
X
X
X
X
X
L
ILLEGAL  
L
X
X
X
X
X
L
X
X
X
X
X
L
NOP (Maintain Self-Refresh)  
INVALID  
H
L
X
H
L
POWER  
DOWN  
Exit Power Down to Idle  
NOP (Maintain Self-Refresh)  
Refer to Function Truth Table  
Enter Self-Refresh  
L
H
H
H
H
H
H
H
L
H
L
ALL BANKS  
IDLE*2  
L
H
L
X
H
H
H
L
X
H
H
L
Enter Power Down  
L
Enter Power Down  
L
L
ILLEGAL  
L
L
X
X
X
X
X
X
X
ILLEGAL  
L
L
X
X
X
X
X
X
ILLEGAL  
X
H
L
X
X
X
X
X
X
X
X
X
X
Refer to Current State =Power Down  
Refer to Function Truth Table  
Begin CLK Suspend at Next Cycle*3  
Exit CLK Suspend at Next Cycle*3  
Maintain CLK Suspend  
H
H
L
ANY STATE  
other than  
listed above  
H
L
L
ABBREVIATIONS:  
H=High Level, L=Low Level, X=Don’t Care  
NOTES:  
1. CKE Low to High transition will re-enable CLK and other inputs asynchronously . A minimum setup time must be  
satisfied before any command other than EXIT.  
2. Power-Down and Self-Refresh can be entered only from the All Banks Idle State.  
3. Must be legal command.  
10  
MITSUBISHI ELECTRIC