MOSEL VITELIC
T
A
= 0
°
C to 70
°
C; V
DD
= 3.3V
±
0.3V, f = 1 MHz
Symbol
C
I1
C
I2
C
ICL
C
I3
C
I4
C
I0
C
SC
V436516Z04VATG-10PC
Capacitance
Parameter
Input Capacitance (A0 to A11, RAS, CAS, WE)
Input Capacitance (CS0)
Input Capacitance (CLK0-CLK1)
Input Capacitance (CKE0)
Input Capacitance (DQMB0-DQMB7)
Input/Output Capacitance (DQ0-DQ63)
Input Capacitance (SCL, SA0-2)
Limit Values
10
10
30
10
10
10
10
Unit
pF
pF
pF
pF
pF
pF
pF
Standby and Refresh Currents
1
T
A
= 0
°
C to 70
°
C, V
CC
= 3.3V
±
0.3V
Symbol Parameter
I
CC
1
Operating Current
Test Conditions
Burst length = 4, CL = 3
t
RC
> = t
RC
(min),
t
CK
> = t
CK
(min), IO = 0 mA
2 Bank Interleave Operation
CKE< = V
IL
(max), t
CK
> = t
CK
(min)
CKE> = V
IH
(min), t
CK
> = t
CK
(min), Input
changed once in 3 cycles
16M x 64
880
Unit
mA
Note
1,2
I
CC
2P
I
CC
2N
Precharged Standby Current in Power
Down Mode
Precharged Standby Current in
Non-Power Down Mode
16
mA
360
mA
CS =
High
I
CC
3P
I
CC
3N
I
CC
4
Active Standby Current in Power
Down Mode
Active Standby Current in Non-Power
Down Mode
Burst Operating Current
CKE< = V
IL
(max), t
CK
> = t
CK
(min)
CKE> = V
IH
(min), t
CK
> = t
CK
(min), Input
changed one time
t
RC
= Infinite, CL = 3,
t
CK
> = t
CK
(min), IO = 0 mA
2 Banks Activated
t
RC
>= t
RC
(min)
CKE = <0,2 V
L-Version
64
mA
480
mA
CS =
High
1, 2
1040
mA
I
CC
5
I
CC
6
Auto Refresh Current
Self Refresh Current
1600
8
4.8
mA
mA
mA
1,2
1,2
V436516Z04VATG-10PC Rev. 1.2 May 2001
6