Both writes must occur before time-out in the order listed, but any number of instruc-  
tions can be executed between the two writes.  
Watchdog clock rate is affected by the software watchdog prescale (SWP) and soft-  
ware watchdog timing (SWT) fields in SYPCR.  
SWP determines system clock prescaling for the watchdog timer and determines that  
one of two options, either no prescaling or prescaling by a factor of 512, can be select-  
ed. The value of SWP is affected by the state of the MODCLK pin during reset, as  
shown in Table 4-3. System software can change SWP value.  
Table 4-3 MODCLK Pin and SWP Bit During Reset  
MODCLK  
SWP  
1 (÷ 512)  
0 (÷ 1)  
0 (External Clock)  
1 (Internal Clock)  
The SWT field selects the divide ratio used to establish software watchdog time-out  
period. Time-out period is given by the following equations.  
1
Time-out Period = ------------------------------------------------------------------------------------  
EXTAL Frequency Divide Ratio  
4
or  
Divide Ratio  
Time-out Period = ------------------------------------------------  
EXTAL Frequency  
Table 4-4 shows the ratio for each combination of SWP and SWT bits. When SWT[1:0]  
are modified, a watchdog service sequence must be performed before the new time-  
out period can take effect.  
Table 4-4 Software Watchdog Ratio  
SWP  
SWT  
00  
Ratio  
9
2
0
0
0
0
1
1
1
1
11  
2
01  
13  
2
10  
15  
2
11  
18  
2
00  
20  
2
01  
22  
2
10  
24  
2
11  
Figure 4-3 is a block diagram of the watchdog timer and the clock control for the pe-  
riodic interrupt timer.  
MOTOROLA  
4-6  
SYSTEM INTEGRATION MODULE  
MC68331  
USER’S MANUAL