Portable, Modular Signal Conditioning Modules
NI SCC-AO10 Isolated Analog Output
Specifications
SCC-AO10
Output Characteristics
Number of output channels ................
Input range..........................................
Output range .......................................
Current drive .......................................
Gain nonlinearity.................................
Propagation delay ...............................
Output noise........................................
Bandwidth ...........................................
Slew rate.............................................
1 nonreferenced single ended
±10 V
±10 V
±30 mA
0.5% of full-scale output range
10 µs
2.5 mV
rms
typ; 4 mV
rms
max
>23 kHz
1 V/µs
Model
SCC-AO10
Channel
1
Description
±10 V isolated voltage output
Part Number
777459-50
The National Instruments SCC-AO10 is a single-channel isolated analog
voltage output module with an output range of ±10 V. Each channel of
the NI SCC-AO10 is referenced to its own isolated ground, allowing up to
60 VDC of common-mode voltage between grounds (channel-to-channel
or channel-to-chassis). In addition, the SCC-AO10 increases the output
current drive capacity of an M Series, E Series, or B Series multifunction
DAQ device to ±30 mA. Because the modules are isolated, you can
cascade two SCC-AO10 modules for an output range of ±20 V. There is
a maximum of two SCC-AO10 modules per carrier.
Note:
Use the SCC-AO10 with only multifunction DAQ devices that have
analog outputs.
Safety Isolation
Channel-to-earth
(signal + common mode) ................ 60 VDC, CAT I
Environment
Operating temperature .......................
Relative humidity ................................
Stability
Output offset temperature
coefficient...................................
Gain temperature coefficient .........
0 to 50 °C
10 to 90% noncondensing
300 µV/°C
300 ppm/°C
Power Requirements
Analog ................................................. 180 mW
Digital.................................................. 1.15 W