欢迎访问ic37.com |
会员登录 免费注册
发布采购

779474-01 参数 Datasheet PDF下载

779474-01图片预览
型号: 779474-01
PDF下载: 下载PDF文件 查看货源
内容描述: SCC配置指南 [SCC Configuration Guide]
分类和应用:
文件页数/大小: 17 页 / 4120 K
品牌: NI [ National Instruments ]
 浏览型号779474-01的Datasheet PDF文件第9页浏览型号779474-01的Datasheet PDF文件第10页浏览型号779474-01的Datasheet PDF文件第11页浏览型号779474-01的Datasheet PDF文件第12页浏览型号779474-01的Datasheet PDF文件第13页浏览型号779474-01的Datasheet PDF文件第15页浏览型号779474-01的Datasheet PDF文件第16页浏览型号779474-01的Datasheet PDF文件第17页  
Portable, Modular Signal Conditioning Modules  
NI SCC-CO20 Isolated Current Output  
NI SCC-DI01 Optically Isolated Digital Input  
Model  
Channel  
Description  
Part Number  
Model  
Channel  
Description  
Part Number  
SCC-C020  
1
Isolated current output  
777459-33  
SCC-DI01  
1
Isolated digital input  
777459-11  
The National Instruments SCC-CO20 is a single-channel isolated current  
output module that can provide up to 20 mA. This module is installation  
rated for CAT I, and provides a safe working voltage of ±0 VDC. Because  
the modules are isolated, you can connect two NI SCC-CO20 modules in  
parallel to provide up to 40 mA.  
The National Instruments SCC-DI01 is a single-channel, optically isolated  
digital input module for sensing digital signals up to 30 VDC, including  
TTL. This digital input module can sense both AC and DC signals and has  
a status LED for visual verification of the module input status.  
The NI SCC-DI01 fits in any SC-2345 socket J9 through J1±. When  
you install an SCC-DI01 in one of these sockets, the digital signal is  
automatically routed to a DIO line of the multifunction DAQ device. For  
The SCC-CO20 plugs into either analog output socket, J17 or J18.  
The voltage applied to the module from an analog output channel of a  
multifunction DAQ device sets the current output. Because there are two example, socket J9 connects to digital line 0 of the data acquisition  
output channels on DAQ devices, there are a maximum of two SCC-CO20 device. Because you can configure multifunction DAQ devices for input  
modules per carrier.  
or output on a line-by-line basis, you can have between one and eight  
SCC-DI01 modules per carrier.  
Note: Use the SCC-CO20 with only multifunction DAQ devices that have  
Specifications  
analog outputs.  
SCC-DI01  
Specifications  
SCC-CO20  
Input Characteristics  
Number of channels............................  
1
Input range.......................................... 30 VDC or 30 VAC  
Output Characteristics  
Number of channels............................  
1
Digital Logic Levels  
Output referencing.............................. Nonreferenced (floating)  
Input range.......................................... 0 to 10 V  
Output range ....................................... 0 to 20 mA  
Voltage compliance............................. 12.5 V  
Input current  
5 V input ......................................... 1.5 mA  
24 V input ....................................... 7.0 mA  
Isolation............................................... 42 VDC from computer ground  
Safety Isolation  
Working common-mode voltage......... ±0 VDC, CAT I  
Power Requirements  
Digital.................................................. ±1 mW  
Environment  
Operating temperature ....................... 0 to 50 °C  
Relative humidity ................................ 10 to 90ꢀ, noncondensing  
Power Requirements  
Analog................................................. 175 mW  
Digital.................................................. ±45 mW  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  