内容描述: 9 kHz至105 MHz的正弦波/ DC至100 MHz的时钟/ 1.07 μHz的频率分辨率 [9 kHz to 105 MHz sine wave/DC to 100 MHz clock/1.07 μHz frequency resolution]
分类和应用: 时钟
文件页数/大小: 6 页 / 786 K
品牌: NI [ NATIONAL INSTRUMENTS CORPORATION ]
 浏览型号NIPXI-5404的Datasheet PDF文件第1页浏览型号NIPXI-5404的Datasheet PDF文件第2页浏览型号NIPXI-5404的Datasheet PDF文件第4页浏览型号NIPXI-5404的Datasheet PDF文件第5页浏览型号NIPXI-5404的Datasheet PDF文件第6页  
100 MHz Frequency Generator
Software
If you want to build an automated test application or integrate the
PXI-5404 in your test software, use the IVI-compliant NI-FGEN
instrument driver with:
• NI LabVIEW
• Microsoft Visual Basic
•NI LabWindows/CVI
•Microsoft Visual C/C++
Interactive Control
The PXI-5404 comes with the versatile Sources Soft Front Panel
with which you can interactively control the PXI-5404. You can
generate sine and clock outputs with control of frequency, phase,
amplitude, and duty cycle with the Sources Soft Front Panel.
Furthermore, you can run the PXI-5404 in simulation mode from
the Sources Soft Front Panel.
NI-FGEN comes with a comprehensive set of examples that
illustrate the programming and features of the PXI-5404 in all four
programming environments. Because NI-FGEN offers simulation
mode, you can run your application on a laptop PC, for example.
Thanks to this feature, you can develop your application with the
PXI-5404 remotely or a team of developers can work on an
application without the need for hardware in their systems.
Ordering Information
NI PXI-5404 ................................................778577-01
Includes the module, NI-FGEN, Sources Soft Front Panel,
and calibration certificate.
Specifications
Specifications are valid for the Operating
Temperature Range, unless otherwuse noted.
CH0 CLOCK (Channel 0 Clock Output, I/O Panel Connector)
Connector ..................................................
Frequency Range .......................................
Frequency Resolution ................................
Phase Range ..............................................
Phase Resolution .......................................
Output Impedance .....................................
Output Protection ......................................
Output
Current
Amplitude
(Open Load)
V
OL
V
OH
Amplitude
(50 Load)
V
OL
V
OH
5.0 V Level
120 mA
5.0 V Level
Min
Max
-0.10 V 0.40 V
4.00 V 5.30 V
5.0 V Level
Min
Max
-0.10 V 0.20 V
2.00 V 2.65 V
3.3 V Level
72 mA
3.3 V Level
Min
Max
-0.10 V 0.40 V
2.60 V 3.70 V
3.3 V Level
Min
Max
-0.10 V 0.20 V
1.30 V 1.85 V
SMB
DC to 105 MHz
1.07 µHz
0 to 359.978 deg
16384 steps including endpoints
50
±12%, (DC to 105 MHz)
+8 to -4 V
Typical
Source or Sink
Output Characteristics
Number of outputs .................................... 1 sine and 1 clock,
Both generate same frequency
simultaneously.
CH0 SINE (Channel 0 Sine Wave Output, I/O Panel Connector)
SMB
9 kHz to 105 MHz
1.07 µHz
0 to 359.978 deg
16384 steps including endpoints
(approximately 0.022 deg)
Output Impedance ..................................... 50
±4% (9 kHz to 105 MHz)
Output Protection ...................................... 10 V
rms
Sampling Rate............................................ 300 MS/s
Amplitude Range
Open load ............................................. 4.00
Vpp
to 2.00
Vpp
50
load .............................................. 2.00
Vpp
to 1.00
Vpp
Amplitude Resolution ................................ 2048 steps including endpoints
(Open Load: Approximately 977 µV.
50
Load: Approximately 489 µV)
Amplitude Accuracy ................................... ±1% @ 50 kHz
Amplitude Passband Flatness.................... ±0.2 dB relative to the amplitude @
50 kHz, 9 kHz < f <105 MHz
Amplitude Temperature Coefficient........... ±0.013% / ºC
Vertical Resolution ..................................... 12 bits @ 4 V
pp
(open load)
11 bits @ 2 V
pp
(open load)
Bandwitdth................................................. 105 MHz (0.2 dB)
Filter ........................................................... Analog 7-pole elliptical
Connector ..................................................
Frequency Range .......................................
Frequency Resolution ................................
Phase Range ..............................................
Phase Resolution .......................................
1.8 V Level
48 mA
1.8 V Level
Min
Max
-0.10 V 0.40 V
1.40 V 2.20 V
1.8 V Level
Min
Max
-0.10 V 0.20 V
0.70 V 1.10 V
If the CH0 CLOCK out signal
is terminated into a 50
load
the voltage levels will be
divided by two.
Rise/Fall Time.............................................
Duty Cycle Range ......................................
Duty Cycle Accuracy .................................
30 to 70%..................................
25 and 75% ...............................
4 ns
25 to 75%
(Typical 1.07 µHz to 60 MHz)
±2%
±3%
PFI 0 (Programmable Function Interface, I/O Panel Connector)
Connector ..................................................
Direction ...................................................
Frequency Range .......................................
As an Input
Destination for Input Signal .......................
SMB
Bidirectional
DC to 20 MHz
1. PXI_Trig <0:7>
( Backplane Connector )
2. REF OUT (I/O Panel
SMB Connector)
3. Start Trigger
1 kΩ ±1%
+8 to -4
2.0 V
0.8 V
+8 to -4V
SINAD
SFDR
THD
Average Noise
Density
+ 51 dB
1 MHz
10 MHz
+ 48 dB
20 MHz
+ 45 dB
+ 42 dB
50 MHz
100 MHz
+ 42 dB
1 MHz
- 55 dBc
10 MHz
- 54 dBc
20 MHz
- 49 dBc
- 45 dBc
50 MHz
- 53 dBc
100 MHz
1 MHz
- 56 dB
10 MHz
- 52 dB
20 MHz
- 48 dB
50 MHz
- 41 dB
100 MHz
- 36 dB
0.126 µVrms /
√Hz
- 125 dBm / Hz
Amplitude set to 1.8
Vpp
(~ –1 dBFS).
Measured from 9 kHz to 150 MHz.
Input Resistance ........................................
Input Protection .........................................
V
IH
...................................................
...................................................
V
IL
Output Protection ......................................
Amplitude 1.8
Vpp
(~ –1 dBFS).
Measured from 9 kHz to 150 MHz
Includes harmonics.
Amplitude 1.8
Vpp
(~ –1 dBFS).
Includes 2nd through the 6th harmonic.
Integrated from 9 kHz to 150 MHz
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com