M29W160ET, M29W160EB
DC AND AC PARAMETERS
This section summarizes the operating measure-
ment conditions, and the DC and AC characteris-
tics of the device. The parameters in the DC and
AC characteristics Tables that follow, are derived
from tests performed under the Measurement
Conditions summarized in Table 9, Operating and
AC Measurement Conditions. Designers should
check that the operating conditions in their circuit
match the operating conditions when relying on
the quoted parameters.
Table 9. Operating and AC Measurement Conditions
M29W160E
Parameter
Min
V
CC
Supply Voltage
Ambient Operating Temperature
Load Capacitance (C
L
)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
0 to V
CC
V
CC
/2
2.7
–40
30
10
0 to V
CC
V
CC
/2
70
Max
3.6
85
Min
2.7
–40
30
10
90
Max
3.6
85
V
°C
pF
ns
V
V
Unit
Figure 9. AC Measurement I/O Waveform
Figure 10. AC Measurement Load Circuit
VCC
VCC
VCC
VCC/2
0V
AI04498
25kΩ
DEVICE
UNDER
TEST
25kΩ
0.1µF
CL
CL includes JIG capacitance
AI04499
Table 10. Device Capacitance
Symbol
C
IN
C
OUT
Parameter
Input Capacitance
Output Capacitance
Test Condition
V
IN
= 0V
V
OUT
= 0V
Min
Max
6
12
Unit
pF
pF
Note: Sampled only, not 100% tested.
20/40