欢迎访问ic37.com |
会员登录 免费注册
发布采购

M29W640GH70NB6E 参数 Datasheet PDF下载

M29W640GH70NB6E图片预览
型号: M29W640GH70NB6E
PDF下载: 下载PDF文件 查看货源
内容描述: 64兆位(8MB X8或X16 4Mb的,页) 3V供应闪存 [64 Mbit (8Mb x8 or 4Mb x16, Page) 3V supply Flash memory]
分类和应用: 闪存存储内存集成电路光电二极管
文件页数/大小: 90 页 / 1676 K
品牌: NUMONYX [ NUMONYX B.V ]
 浏览型号M29W640GH70NB6E的Datasheet PDF文件第22页浏览型号M29W640GH70NB6E的Datasheet PDF文件第23页浏览型号M29W640GH70NB6E的Datasheet PDF文件第24页浏览型号M29W640GH70NB6E的Datasheet PDF文件第25页浏览型号M29W640GH70NB6E的Datasheet PDF文件第27页浏览型号M29W640GH70NB6E的Datasheet PDF文件第28页浏览型号M29W640GH70NB6E的Datasheet PDF文件第29页浏览型号M29W640GH70NB6E的Datasheet PDF文件第30页  
Command Interface  
M29W640GH, M29W640GL, M29W640GT, M29W640GB  
It is also possible to issue the Auto Select, Read CFI Query and Unlock Bypass commands  
during an Erase Suspend. The Read/Reset command must be issued to return the device to  
Read Array mode before the Resume command will be accepted.  
4.1.7  
4.1.8  
Erase Resume command  
The Erase Resume command must be used to restart the Program/Erase Controller after an  
Erase Suspend. The device must be in Read Array mode before the Resume command will  
be accepted. An erase can be suspended and resumed more than once.  
Program Suspend command  
The Program Suspend command allows the system to interrupt a program operation so that  
data can be read from any block. When the Program Suspend command is issued during a  
program operation, the device suspends the program operation within the Program Suspend  
Latency time (see Table 12: Program, Erase times and endurance cycles for value) and  
updates the Status Register bits.  
After the program operation has been suspended, the system can read array data from any  
address. However, data read from Program-Suspended addresses is not valid.  
The Program Suspend command may also be issued during a program operation while an  
erase is suspended. In this case, data may be read from any addresses not in Erase  
Suspend or Program Suspend. If a read is needed from the Extended Block area (One-time  
Program area), the user must use the proper command sequences to enter and exit this  
region.  
The system may also issue the Auto Select command sequence when the device is in the  
Program Suspend mode. The system can read as many Auto Select codes as required.  
When the device exits the Auto Select mode, the device reverts to the Program Suspend  
mode, and is ready for another valid operation. See Auto Select command sequence for  
more information.  
4.1.9  
Program Resume command  
After the Program Resume command is issued, the device reverts to programming. The  
controller can determine the status of the program operation using the DQ7 or DQ6 status  
bits, just as in the standard program operation. See Write Operation Status for more  
information.  
The system must write the Program Resume command, to exit the Program Suspend mode  
and to continue the programming operation.  
Further issuing of the Resume command is ignored. Another Program Suspend command  
can be written after the device has resumed programming.  
26/90