 浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第17页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第18页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第19页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第20页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第22页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第23页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第24页浏览型号M58LT128HSB8ZA6E的Datasheet PDF文件第25页  
M58LT128HST, M58LT128HSB
Command interface
4.7
Blank Check command
The Blank Check command is used to check whether a block has been completely erased.
Only one block at a time can be checked. To use the Blank Check command, V
PP
must be
equal to V
PPH
. If V
PP
is not equal to V
PPH
, the device ignores the command and no error is
shown in the Status Register.
The following two bus cycles are required to issue the Blank Check command:
The first bus cycle writes the Blank Check command (BCh) to any address in the block
to be checked.
The second bus cycle writes the Blank Check Confirm command (CBh) to any address
in the block to be checked and starts the Blank Check operation.
If the second bus cycle is not Blank Check Confirm, Status Register bits SR4 and SR5 are
set to '1' and the command aborts.
Once the command is issued the addressed bank automatically enters the Status Register
mode and further reads the Status Register contents within the bank output.
The only operation permitted during Blank Check is Read Status Register. Dual operations
are not supported while a Blank Check operation is in progress. Blank Check operations
cannot be suspended and are not allowed while the device is in Program/Erase Suspend.
The SR7 Status Register bit indicates the status of the Blank Check operation in progress:
SR7 = '0' means that the Blank Check operation is still ongoing, and SR7 = '1' means that
the operation is complete.
The SR5 Status Register bit goes High (SR5 = '1') to indicate if the Blank Check operation
has failed.
At the end of the operation the bank remains in the Read Status Register mode until another
command is written to the Command Interface.
See
for a suggested
flowchart for using the Blank Check command.
Typical Blank Check times are given in
21/110