Dimensions
Note: 1.
Unless otherwise specified, all units are in millimeters and a tolerance of
±0.4
mm applies to all dimensions
2.
The operating characteristics are for operation in the A direction( )
Pin Plunger Models
D3M-01
D3M-01-3
(7.2)
OF max
RF min.
PT max.
(see note 2)
A
3.5
7.6
153 gf
25 gf
0.6 mm
0.4 mm
0.1 mm
8.4
±
0.3 mm
OT min.
MD max.
OP
FP
(see note 2)
2.5
2.35
+0.1
7.7
–0.05
10
OP
7
(see note 1)
2.35
+0.1
dia.
–0.05
2.5 dia.
9.5
±0.1
29.2
5.7
(31.6)
Note:
1. The terminals connect to JST’s Dipole XA Connector.
2. The Dipole XA Connector consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
Hinge Lever Models (K)
D3M-01K1
D3M-01K1-3
(7.2)
OF max
RF min.
OT min.
(see note 2)
A
3.6
(see note 2)
FP
2.5
2.35
+0.1
7.7
–0.05
OP
10
Stainless steel (t = 0.3)
1
8
.2
12.9
51 gf
6 gf
1.2 mm
0.8 mm
14.0 mm
10.0
±
0.8 mm
MD max.
FP max.
OP
7
2.5 dia.
(see note 1)
+0.1
9.5
±0.1
2.35
–0.05
dia.
29.2
(31.6)
5.7
Note:
1. The terminals connect to JST’s Dipole XA Connector.
2. The Dipole XA Connector consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
Hinge Lever Models (L)
D3M-01L1
D3M-01L1-3
(7.2)
OF max
RF min.
(see note 2)
Stainless steel (t = 0.3)
102 gf
10 gf
0.7 mm
0.6 mm
11.5 mm
9.2
±
0.6 mm
OT min.
MD max.
FP max.
OP
FP
1
8
.2
3.6
(see note 2)
2.35
+0.1
7.7
–0.05
OP
10
2.4
A
2.5
7
(see note 1)
2.35
+0.1
dia.
–0.05
2.5 dia.
9.5
±0.1
29.2
(31.6)
5.7
Note:
1. The terminals connect to JST’s Dipole XA Connector.
2. The Dipole XA Connector consists of the following components.
Contact: SXA-001T-P0.6
Housing: XAP-02V-1
Subminiature Snap Action Switch
D3M
59