2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
SIGNAL
LEVEL
VCC
VCC
0
≦
t
VSS
VCC
VSS
VCC
SIGNAL
0
≦
t
VEE
VSS
VEE
0
≦
t
VCC
VSS
DISPOFF
2.6.2.OFF Sequence
LEVEL
VCC
VSS
VCC
VSS
VCC
VSS
VEE
VCC
VSS
0
≦
t
0
≦
t
SIGNAL
VCC
0
≦
t
SIGNAL
VEE
DISPOFF
Please maintain the above sequence when turning on and off the power supply of the module.
If DISPOFF is supplied to the module
w
hile alternate signal for LCD driving (M) is unstable,
DC component will be supplied to the LCD panel. This may cause damage the LCD module.