2.7.Lighting Specifications
Ta=25℃
Parameter
Lamp Voltage
Lamp Current
Starting Voltage
Surface Luminance
Symbol
V
L
I
L
V
S
L
Conditions
-
-
-
I
L
=5.0mA
Min.
-
4.0
600
50
Typ.
250
5.0
-
-
Max.
-
6.0
-
-
Units
Vrms
mArms
Vrms
cd/㎡
Notes
1
2
3
4
Average Life
T
AL
I
L
=5.0mA
20000
hrs
5
-
-
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for
3 minutes .
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after
lighting for 3 minutes.
Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V.
Note 4 : Surface Luminance is specified by the initial data of luminance measured at the center of display
surface after 20 minutes power on. ( All ON pattern )
Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the residual
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life
mentioned above.
I
N
V
VS
VL
C
F
L
IL
CFL Testing Circuit
DMF6104NF-FW
(AE)
No.97-0106
OPTREX
OPTREX CORPORATION
Page 7/17