Philips Semiconductors
Product specification
Dual inverter
74LVC2G04
RECOMMENDED OPERATING CONDITIONS
SYMBOL
VCC
PARAMETER
supply voltage
CONDITIONS
MIN.
1.65
MAX.
5.5
UNIT
V
VI
input voltage
0
5.5
VCC
5.5
+125
20
V
VO
output voltage
active mode
0
V
VCC = 0 V; Power-down mode
0
V
Tamb
tr, tf
operating ambient temperature
input rise and fall times
−40
0
°C
VCC = 1.65 V to 2.7 V
VCC = 2.7 V to 5.5 V
ns/V
ns/V
0
10
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134); voltages are referenced to GND (ground = 0 V).
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
VCC supply voltage −0.5 +6.5
V
IIK
input diode current
input voltage
VI < 0 V
note 1
−
−50
mA
V
VI
−0.5
−
+6.5
±50
IOK
VO
output diode current
output voltage
VO > VCC or VO < 0 V
mA
V
active mode; notes 1 and 2
−0.5
VCC + 0.5
+6.5
±50
Power-down mode; notes 1 and 2 −0.5
V
IO
output source or sink current
VCC or GND current
storage temperature
power dissipation
VO = 0 V to VCC
−
mA
mA
°C
mW
ICC, IGND
Tstg
−
±100
+150
300
−65
−
PD
Tamb = −40 °C to +125 °C
Notes
1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. When VCC = 0 V (Power-down mode), the output voltage can be 5.5 V in normal operation.
2004 Sep 15
5