欢迎访问ic37.com |
会员登录 免费注册
发布采购

PFC500-1048 参数 Datasheet PDF下载

PFC500-1048图片预览
型号: PFC500-1048
PDF下载: 下载PDF文件 查看货源
内容描述: 高性能电源 [PerFormanCe POWER]
分类和应用:
文件页数/大小: 4 页 / 209 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号PFC500-1048的Datasheet PDF文件第2页浏览型号PFC500-1048的Datasheet PDF文件第3页浏览型号PFC500-1048的Datasheet PDF文件第4页  
PerFormanCe POWER PFC500
The PFC500 products of the PerFormanCe Power series combine high
performance midrange power with high power density (4.4 watts/in
3
),
active Power Factor Correction (PFC) and high reliability to meet the
requirements of commercial and industrial systems.
Providing tightly regulated DC power, the PFC500 is delivers full
output performance with only 300 Linear Feet per Minute (LFM)
forced air cooling (factory installed fan optional). Other features
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Fully Regulated Outputs
• Remote Sense
• Current Share, Power Fail, and Power Good Signals
• Overtemperature, Overvoltage, and Overcurrent Protected
• Available with Metric or SAE Mountings
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5
• Fan Output Voltage and Optional Fan
• Optional Isolation Diodes for Parallel or Redundant Operation
include remote sense, power fail, logic level inhibit, DC power good.
Main channel current sharing is provided for redundant applications.
The PFC500 is available with SAE mountings or optional metric
mountings.
The PFC500 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION (NOTE 3)
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
PFC500-1024
PFC500-1028
PFC500-1048
NOTES:
24V
28V
48V
21.6V to 26.4V
25.2V to 30.8V
46.0V to 56.0V
21A
17.9A
10.4A
0.5%
0.5%
0.5%
0.2%
0.2%
0.5%
1%
1%
1%
23.88V to 24.12V
27.86V to 28.14V
47.52V to 48.48V
1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
3) Remote sense connected.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse, F10A, 250V.
Internally limited by thermistor, one cycle, 25°C.
110 VAC
220 VAC
85
47
85
20
264
63
7.8
35
65
0.98
100
VAC
Hz
VAC
mS
A
RMS
A
PK
W/VA
kHz
Per EN61000-3-2.
Switching frequency of main transformer.
Rev. 04/2000
1