ZY7010L 10A DC-DC Intelligent POL Data Sheet
3V to 13.2V Input
•
0.5V to 5.5V Output
Figure 1. Output Voltage as a Function of Input Voltage and Output Current
4.3
Protection Specifications
Parameter
Conditions/Description
Output Overcurrent Protection
Type
Threshold
Threshold Accuracy
Output Overvoltage Protection
Type
Threshold
Threshold Accuracy
Delay
Default
Programmable
Default
Programmable in 10% steps
Measured at V
O.SET
=2.5V
From instant when threshold is exceeded until
the turn-off command is generated
Non-Latching, 130ms period
Latching/Non-Latching
130
%V
O.SET
130
%V
O.SET
2
6
%V
OVP.SET
µs
Default
Programmable
Default
Programmable in 11 steps
Non-Latching, 130ms period
Latching/Non-Latching
150
%I
OUT
150
%I
OUT
25
%I
OCP.SET
Min
Nom
Max
Units
50
-25
110
1
-2
ZD-00422 REV. 2.2
www.power-one.com
Page 4 of 34