ZY7010L 10A DC-DC Intelligent POL Data Sheet
3V to 13.2V Input
•
0.5V to 5.5V Output
Output Undervoltage Protection
Type
Threshold
Threshold Accuracy
Delay
Default
Programmable
Default
Programmable in 5% steps
Measured at V
O.SET
=2.5V
From instant when threshold is exceeded until
the turn-off command is generated
Overtemperature Protection
Type
Turn Off Threshold
Turn On Threshold
Threshold Accuracy
Delay
From instant when threshold is exceeded until
the turn-off command is generated
Tracking Protection (when Enabled)
Type
Threshold
Threshold Accuracy
Delay
From instant when threshold is exceeded until
the turn-off command is generated
Overtemperature Warning
Threshold
Threshold Accuracy
Hysteresis
Delay
From instant when threshold is exceeded until
the warning signal is generated
Power Good Signal (PGOOD pin)
Logic
Lower Threshold
Upper Threshold
Delay
Threshold Accuracy
From instant when threshold is exceeded until
status of PG signal changes
Measured at V
O.SET
=2.5V
-2
V
OUT
is inside the PG window
V
OUT
is outside the PG window
Default
Programmable in 5% steps
High
Low
90
90
110
6
2
95
N/A
%V
O.SET
%V
O.SET
%V
O.SET
µs
%V
O.SET
Always enabled, reported in Status register
-5
3
6
120
5
°C
°C
°C
µs
Default
Programmable
Enabled during output voltage ramping up
-50
6
Disabled
Latching/Non-Latching, 130ms period
±250
50
mVDC
mVDC
µs
Default
Programmable
Temperature is increasing
Temperature is decreasing after the module was
shut down by OTP
-5
6
Non-Latching, 130ms period
Latching/Non-Latching
130
120
5
°C
°C
°C
µs
Non-Latching, 130ms period
Latching/Non-Latching
75
%V
O.SET
85
%V
O.SET
2
6
%V
UVP.SET
µs
75
-2
___________________
1
Minimum OVP threshold is 1.0V
ZD-00422 REV. 2.2
www.power-one.com
Page 5 of 34