November 2006
rev 1.4
Operating Conditions for ASM5I23S04A Industrial Temperature Devices
Parameter
V
DD
T
A
C
L
C
L
C
IN
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance, below 100 MHz
Load Capacitance, from 100 MHz to 133 MHz
Input Capacitance
6
ASM5P23S04A
Description
Min
3.0
-40
Max
3.6
85
30
15
7
Unit
V
°C
pF
pF
pF
Note:
6. Applies to both Ref Clock and FBK.
Electrical Characteristics for ASM5I23S04A Industrial Temperature Devices
Parameter
V
IL
V
IH
I
IL
I
IH
Description
Input LOW Voltage
Input HIGH Voltage
Input LOW Current
Input HIGH Current
V
IN
= 0V
V
IN
= V
DD
Test Conditions
Min
Max
0.8
Unit
V
V
2.0
50.0
100.0
µA
µA
V
OL
Output LOW Voltage
7
I
OL
= 8mA (-1, -2)
I
OH
= 12mA (-1H, -2H)
I
OL
= -8mA (-1, -2)
I
OH
= -12mA (-1H, -2H)
Unloaded outputs 100MHz REF, Select
inputs at V
DD
or GND
0.4
V
V
OH
Output HIGH Voltage
7
2.4
V
TBD
TBD
TBD
TBD
I
DD
Supply Current
Unloaded outputs, 66MHz REF (-1, -2)
Unloaded outputs, 33MHz REF (-1, -2)
mA
Note:
7. Parameter is guaranteed by design and characterization. Not 100% tested in production.
3.3 ‘SpreadTrak’ Zero Delay Buffer
Notice: The information in this document is subject to change without notice.
7 of 15