FM25L16
Electrical Specifications
Absolute Maximum Ratings
Symbol
Description
V
DD
Power Supply Voltage with respect to V
SS
V
IN
Voltage on any pin with respect to V
SS
T
STG
T
LEAD
V
ESD
Storage Temperature
Lead Temperature (Soldering, 10 seconds)
Electrostatic Discharge Voltage
- Human Body Model
(JEDEC Std JESD22-A114-B)
- Charged Device Model
(JEDEC Std JESD22-C101-A)
Package Moisture Sensitivity Level
Ratings
-1.0V to +5.0V
-1.0V to +5.0V
and V
IN
< V
DD
+1.0V
-55°C to + 125°C
300° C
4kV
1kV
MSL-1
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating
only, and the functional operation of the device at these or any other conditions above those listed in the operational section of this
specification is not implied. Exposure to absolute maximum ratings conditions for extended periods may affect device reliability.
DC Operating Conditions
(T
A
= -40° C to + 85° C, V
DD
= 2.7V to 3.6V unless otherwise specified)
Symbol
Parameter
Min
Typ
Max
Units
V
DD
Power Supply Voltage
2.7
3.3
3.6
V
I
DD
VDD Supply Current
mA
0.3
0.15
@ SCK = 1.0 MHz
mA
5.5
3.0
@ SCK = 18.0 MHz
I
SB
Standby Current
-
1
µA
I
LI
Input Leakage Current
-
±1
µA
I
LO
Output Leakage Current
-
±1
µA
V
IH
Input High Voltage
0.7 V
DD
V
DD
+ 0.5
V
V
IL
Input Low Voltage
-0.3
0.3 V
DD
V
V
OH
Output High Voltage
-
V
V
DD
– 0.8
@ I
OH
= -2 mA
V
OL
Output Low Voltage
-
0.4
V
@ I
OL
= 2 mA
V
HYS
Input Hysteresis
(/CS and SCK only)
0.05 V
DD
-
V
Notes
1.
SCK toggling between V
DD
-0.3V and V
SS
, other inputs V
SS
or V
DD
-0.3V.
2.
SCK = SI = /CS=V
DD
. All inputs V
SS
or V
DD
.
3.
V
SS
≤
V
IN
≤
V
DD
and V
SS
≤
V
OUT
≤
V
DD
.
4.
Characterized but not 100% tested in production.
Notes
1
2
3
3
4
Rev. 3.0
Aug. 2006
Page 9 of 14