POWERLINE
DC/DC-Converter
RP40-S_D_TE
Series
RP40-4805SE
125
100
75
Output Power (%)
50
25
0
-40 -25 -10 0
50 60
70 80 90 100
55°C
Derating-Graph
(Ambient Temperature)
Natural Convection
Ambient Temperature Range (°C)
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at info@recom-development.at
Typical Characteristics
RP40-4805SE
Efficiency VS Input Voltage
91
90
89
88
87
86
85
84
83
82
81
80
91
90
89
88
86
84
82
80
70
60
50
45
RP40-4805SE
Efficiency VS Output Load
Efficiency (%)
Efficiency (%)
36
40
45
50
55
60
65
70
75
0,5
1
2
3
4
5
6
7
8
Input Voltage (V)
Output Load (A)
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
9-18VDC
18-36VDC
36-75VDC
Pi Type
12V Input
24V Input
48V Input
36VDC
50VDC
100VDC
40mAp-p
DC-DC ON
DC-DC OFF
Nominal input
Single & Dual
Triple 3.3V, 5V
Auxiliary
25ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
30mA
40W max.
±2%
±2%
±5%
continued on next page
www.recom-international.com
21-July-2005
249
Input Filter
Input Surge Voltage (100 ms max.)
Input Reflected Ripple (nominal Vin and full load)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 7)
Remote OFF input current
Output Power
Output Voltage Accuracy (full Load and nominal Vin)