Specifications
(typical at nominal input and 25°C unless otherwise noted)
Voltage Adjustability
Minimum Load
Line Regulation (LL-HL at full load)
RP40-S_D_TE
Series
±10%
RP40-xx3.305DE
others
Single
Dual
Triple 3.3V, 5V
Auxiliary
Single
Dual
Triple 3.3V, 5V
Auxiliary
Dual
Triple 3.3V, 5V
Auxiliary
20% min.
10% of FL
±0.5%
±1%
±2%
±5%
±0.5%
±1%
±2%
±5%
±1%
±1%
±5%
1%/p-p of Vout max.
±0.02%/°C, max.
3.3V
5V
12V
15V
500µS
3.9V
6.2V
15V
18V
Hiccup, automatic recovery
see „Selection Guide“ table
1.600VDC min.
10
9
Ω
min.
500pF max.
185kHz typ.
-40°C to +85°C(with derating)
+100°C
Natural convection
-55°C to +105°C
7.3°C/Watt
MIL-STD-810D
10-55Hz, 2G, 30 Min. along X, Y and Z
5% to 95% RH
Nickel-Coated copper
Non-conductive black plastic FR4
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
48g
76.2 x 66.0 x 10.2mm
1.315 x 10
6
Hours
Load Regulation (25% to 100% FL)
Cross Regulation (Note 8)
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
Short Circuit Protection
Efficiency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Operating Frequency
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
Thermal Shock
Vibration
Relative Humidity
Case Material
Base Material
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Weight
Dimensions
MTBF (see note 2)
250
21-July-2005