RF5110G
Application Schematic
150MHz FM Band
VAPC
VAPC
VCC
VCC
+
VCC1
10 nF
1 nF
27 pF
8.2 nH
16
1
100 pF
RF IN
180
Ω
3
4
5
6
7
8
10
9
50 mils
10 nF
10 nF
47 pF
3.3
μF
15
14
13
12
11
1 nF
2
1
μH
1
Taiyo Yuden
NR3012T1R0N
100 pF
RF OUT
C11
2
56 pF
C10
33 pF
L4
15 nH
VCC2
+
3.3
μF
10 nF
0
Ω
1 nF
33 nH
27 pF
1
Requires
2
C11
layout change to standard evaluation board.
adjacent to L4.
Application Schematic
220MHz FM Band
VAPC
VAPC
VCC
VCC
+
VCC1
10 nF
1 nF
27 pF
8.2 nH
16
1
2
100 pF
RF IN
180
Ω
3
4
5
6
7
8
10
C10
2
9
33 pF
C11
3
39 pF
15
14
13
12
11
1
μH
1
Taiyo Yuden
NR3012T1R0N
10 nF
10 nF
47 pF
3.3
μF
1 nF
10 nH
100 pF
RF OUT
0
Ω
VCC2
+
3.3
μF
10 nF
1 nF
33 nH
27 pF
layout change to standard evaluation board.
is adjacent to L4.
3
C11 is 140 mils from L4.
2
C10
1
Requires
10 of 22
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Rev A4 DS071026