PM9103AP
ELECTRICAL CHARACTERISTICS
(Over the temperature range -10°C to +70°C, unless otherwise specified. Power
consumption figures are applicable to the PM9103APE only.)
Parameter
Supply Voltage
(Continuous)
Power Measurement
range
Power Consumption
1
Symbol
V
AC
P
RNG
Min
Typ
Max
265
135
18400
800
Unit
V
V
W
mW
Condition
PM9103APE
PM9103APA
Specified
accuracy
V
AC
= 230V
Supply direct
from mains
Continuous
V
OL
= 1V
180
230
90
115
-18400
Isolation Voltage
2
Opto-coupler Output
Current
Opto-coupler Input
Current
V
IS
I
O
I
I
2500
10
10
V
mA
mA
Note 1: Power consumption specifications exclude power consumed by the current
sensor.
Note 2: Isolation voltage may be specified, depending on customer requirements.
CONNECTION DESCRIPTION
Designation
Description
Voltage supply connection to Neutral line
MAINS
Voltage supply connection to Live line
NEUTRAL IN
Connection to positive side of current sensor
NEUTRAL OUT
SK1
D-sub connector
9-Pin
Connection to negative side of current sensor
Serial Input
Serial Output
sames
3/10