40PC Series
Fully signal conditioned pressure transducer
40PC030G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
30
Unit
psig
Zero pressure offset
Span4
0.46
3.92
0.50
4.00
4.5
0.54
4.08
V
Full scale output
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±1.5
±2.0
±2.25
±1.5
±2.0
±2.25
±2.0
%FSS
Combined offset and span -18 to +63°C
-45 to +125°C
±2.25
±2.25
±0.3
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
40PC100G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
100
Unit
psig
Zero pressure offset
Span4
0.46
3.91
0.50
4.0
0.54
4.09
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±1.25
±2.0
±3.0
±0.75
±1.0
±2.0
±1.5
±2.5
±3.0
±3.0
±0.1
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
November 2007 / 573
5/8
www.sensortechnics.com