1. Configuration of data communication
Rev.2.4
_00
For data communication, the master device in the system generates a start condition for the S-35390A. Next, the master
device transmits 4-bit device code “0110”, 3-bit command and 1-bit Read/Write command to the SDA bus. After that,
output or input is performed from B7 of data. If data I/O has been completed, finish communication by inputting a stop
condition to the S-35390A. The master device generates an acknowledgment signal for every 1-byte. Regarding details,
refer to “
Serial Interface
”.
Start condition
Device code
STA
0
1
1
0
C2
Command
C1
C0
Read/Write bit
Acknowledgment bit
R/W
ACK
Stop condition
1-byte data
B7
B6
B5
B4
B3
B2
B1
B0
ACK
STP
Figure 10
Data Communication
8