欢迎访问ic37.com |
会员登录 免费注册
发布采购

C8051F827-GS 参数 Datasheet PDF下载

C8051F827-GS图片预览
型号: C8051F827-GS
PDF下载: 下载PDF文件 查看货源
内容描述: 混合信号ISP功能的Flash MCU系列 [Mixed Signal ISP Flash MCU Family]
分类和应用: 微控制器和处理器外围集成电路光电二极管时钟
文件页数/大小: 250 页 / 1303 K
品牌: SILICON [ SILICON ]
 浏览型号C8051F827-GS的Datasheet PDF文件第161页浏览型号C8051F827-GS的Datasheet PDF文件第162页浏览型号C8051F827-GS的Datasheet PDF文件第163页浏览型号C8051F827-GS的Datasheet PDF文件第164页浏览型号C8051F827-GS的Datasheet PDF文件第166页浏览型号C8051F827-GS的Datasheet PDF文件第167页浏览型号C8051F827-GS的Datasheet PDF文件第168页浏览型号C8051F827-GS的Datasheet PDF文件第169页  
C8051F80x-83x  
SFR Definition 24.4. CRC0AUTO: CRC Automatic Control  
Bit  
7
6
5
4
3
2
1
0
AUTOEN CRCCPT Reserved  
CRC0ST[4:0]  
Name  
Type  
Reset  
R/W  
0
1
0
0
0
0
0
0
SFR Address = 0xD2  
Bit  
Name  
Function  
Automatic CRC Calculation Enable.  
7
AUTOEN  
When AUTOEN is set to 1, any write to CRC0CN will initiate an automatic CRC  
starting at Flash sector CRC0ST and continuing for CRC0CNT sectors.  
6
5
CRCCPT  
Reserved  
Automatic CRC Calculation Complete.  
Set to 0 when a CRC calculation is in progress. Code execution is stopped during  
a CRC calculation, therefore reads from firmware will always return 1.  
Must write 0.  
4:0 CRC0ST[4:0] Automatic CRC Calculation Starting Flash Sector.  
These bits specify the Flash sector to start the automatic CRC calculation. The  
starting address of the first Flash sector included in the automatic CRC calculation  
is CRC0ST x 512.  
SFR Definition 24.5. CRC0CNT: CRC Automatic Flash Sector Count  
Bit  
7
6
5
4
3
2
1
0
CRC0CNT[5:0]  
R/W  
Name  
Type  
Reset  
R
0
R
0
0
0
0
0
0
0
SFR Address = 0xD3  
Bit  
Name  
Function  
7:6  
Unused  
Read = 00b; Write = Don’t Care.  
5:0 CRC0CNT[5:0] Automatic CRC Calculation Flash Sector Count.  
These bits specify the number of Flash sectors to include when performing an  
automatic CRC calculation. The base address of the last flash sector included in  
the automatic CRC calculation is equal to (CRC0ST + CRC0CNT) x 512.  
Rev. 1.0  
165