Table 1. SKY65336-11 Signal Descriptions
Pin #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Note:
Production quantities of this product are shipped in a standard
tape and reel format. For packaging details, refer to the Skyworks
Application Note,
Tape and Reel,
document number 101568.
Name
BIAS1_PASS
TX_N
TX_P
GND
GND
BIAS2_PASS
RX_N
RX_P
GND
GND
RX_VCC
RX_EN
GND
GND
Description
Transmit port bias supply
Negative transmit input port
Positive transmit input port
Ground
Ground
Receive port bias supply
Negative receive output port
Positive receive output port
Ground
Ground
Receive DC supply, +3 V
Receive enable
Ground
Ground
Pin #
15
16
17
18
19
20
21
22
23
24
25
26
27
28
GND
GND
GND
ANT
GND
GND
GND
GND
GND
Name
Ground
Ground
Ground
Antenna input
Ground
Ground
Ground
Ground
Ground
Description
TX_VCC
GND
TX_HLB
TX_EN
T_R
Transmit DC supply, +3 V
Ground
Transmit power mode
Transmit enable
Transmit/receive switch
The bottom ground pad
must be
connected to RF ground.
Table 2. SKY65336-11 Absolute Maximum Ratings (Note 1)
Parameter
Supply voltage
Control Voltage
Symbol
RX_VCC, TX_VCC
BIAS1_PASS,
BIAS2_PASS, TX_EN,
RX_EN, TX_HLB, T_R
BIAS1_PASS, BIAS2_PASS
P
IN
_
ANT
P
IN
_
TX
T
C
T
ST
T
J
–40
–55
Minimum
2.1
Maximum
4
3.6
Units
V
V
Bypass voltage
RF input power, antenna port
RF input power, transmit port
Case operating temperature
Storage temperature
Junction temperature
1.9
10
+8
+85
+125
+150
V
dBm
dBm
C
C
C
Note 1:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION:
Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
200939G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 11, 2009
3