1 Megabit Page-Mode EEPROM
SST29EE010 / SST29LE010 / SST29VE010
T
ABLE
3: O
PERATION
M
ODES
S
ELECTION
Mode
Read
Page-Write
Standby
Write Inhibit
Write Inhibit
Software Chip-Erase
Product Identification
Hardware Mode
Software Mode
SDP Enable Mode
SDP Disable Mode
CE#
V
IL
V
IL
V
IH
X
X
V
IL
V
IL
V
IL
V
IL
V
IL
OE#
V
IL
V
IH
X
V
IL
X
V
IH
V
IL
V
IH
V
IH
V
IH
WE#
V
IH
V
IL
X
X
V
IH
V
IL
V
IH
V
IL
V
IL
V
IL
DQ
D
OUT
D
IN
High Z
High Z/ D
OUT
High Z/ D
OUT
D
IN
Manufacturer ID (BF)
Device ID (see notes)
Address
A
IN
A
IN
X
X
X
A
IN
, See Table 4
A
16
- A
1
= V
IL
, A
9
= V
H
, A
0
= V
IL
A
16
- A
1
= V
IL
, A
9
= V
H
, A
0
= V
IH
See Table 4
See Table 4
See Table 4
304 PGM T3.0
T
ABLE
4: S
OFTWARE
C
OMMAND
C
ODES
Command
Sequence
Software Data
Protect Enable
& Page-Write
Software Data
Protect Disable
Software Chip-
Erase
Software ID Entry
Software ID Exit
1st Bus
Write Cycle
Addr
(1)
Data
5555H AAH
2nd Bus
Write Cycle
Addr
(1)
Data
2AAAH 55H
3rd Bus
Write Cycle
Addr
(1)
Data
5555H A0H
4th Bus
Write Cycle
Addr
(1)
Data
Addr
(2)
Data
5th Bus
Write Cycle
Addr
(1)
Data
6th Bus
Write Cycle
Addr
(1)
Data
5555H AAH
5555H AAH
5555H
5555H
AAH
AAH
AAH
2AAAH
2AAAH
2AAAH
2AAAH
2AAAH
55H
55H
55H
55H
55H
5555H
5555H
5555H
5555H
5555H
80H
80H
90H
F0H
80H
5555H
5555H
AAH
AAH
2AAAH
2AAAH
55H
55H
5555H 20H
5555H 10H
Alternate Software 5555H
ID Entry
(3)
Notes:
(1)
(2)
5555H
AAH
2AAAH
55H
5555H
60H
304 PGM T4.1
Address format A
14
-A
0
(Hex), Addresses A
15
and A
16
are a “Don’t Care”.
Page-Write consists of loading up to 128 Bytes (A
6
- A
0
).
(3)
Alternate six-byte software Product-ID Command Code
(4)
The software Chip-Erase function is not supported by the industrial temperature part.
Please contact SST, if you require this function for an industrial temperature part.
Notes for Software Product ID Command Code:
1. With A
14
-A
1
=0; SST Manufacturer ID = BFH, is read with A
0
= 0,
SST29EE010 Device ID = 07H, is read with A
0
= 1.
SST29LE010/29VE010 Device ID = 08H, is read with A
0
= 1.
2. The device does not remain in Software Product ID Mode if powered down.
3. This device supports both the JEDEC standard three-byte command code sequence and SST’s original six-byte command code
sequence. For new designs, SST recommends the three-byte command code sequence be used.
© 2000 Silicon Storage Technology, Inc.
6