 浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第1页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第2页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第3页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第4页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第6页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第7页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第8页浏览型号SST39WF1601-90-4C-B3KE的Datasheet PDF文件第9页  
16 Mbit Multi-Purpose Flash Plus
SST39WF1601 / SST39WF1602
Preliminary Specifications
Common Flash Memory Interface (CFI)
The SST39WF1601/1602 contain the CFI information to
describe the characteristics of the device. The
SST39WF1601/1602 support the original SST CFI Query
mode implementation for compatibility with existing SST
devices as well as the general CFI Query mode. Both will
be explained in subsequent paragraphs.
In order to enter the SST CFI Query mode, the system
must write the three-byte sequence, same as the product
ID entry command with 98H (CFI Query command) to
address 5555H in the last byte sequence. Once the device
enters CFI Query mode, the system can read CFI data at
the addresses given in Tables 7 through 9. The system
must write the CFI Exit command to return to Read mode
from the CFI Query mode.
In order to enter the general CFI Query mode, the system
must write a one-byte sequence with entry command with
98H to address 55H. Once the device enters the CFI
Query mode, the system can read CFI data at the
addresses given in Tables 7 through 9. The system must
write the CFI Exit command to return to Read mode from
the CFI Query mode.
Product Identification Mode Exit/
CFI Mode Exit
In order to return to the standard Read mode, the Software
Product Identification mode must be exited. Exit is accom-
plished by issuing the Software ID Exit command
sequence, which returns the device to the Read mode.
This command may also be used to reset the device to the
Read mode after any inadvertent transient condition that
apparently causes the device to behave abnormally, e.g.,
not read correctly. Please note that the Software ID Exit/
CFI Exit command is ignored during an internal Program or
Erase operation. See Table 6 for software command
codes, Figure 14 for timing waveform, and Figures 22 and
Security ID
The SST39WF1601/1602 devices offer a 256-bit Security
ID space. The Secure ID space is divided into two 128-bit
segments - one factory programmed segment and one
user programmed segment. The first segment is pro-
grammed and locked at SST with a random 128-bit num-
ber. The user segment is left un-programmed for the
customer to program as desired.
To program the user segment of the Security ID, the user
must use the Security ID Word-Program command. To
detect end-of-write for the SEC ID, read the toggle bits. Do
not use Data# Polling. Once this is complete, the Sec ID
should be locked using the User Sec ID Program Lock-Out.
This disables any future corruption of this space. Note that
regardless of whether or not the Sec ID is locked, neither
Sec ID segment can be erased.
The Secure ID space can be queried by executing a three-
byte command sequence with Enter Sec ID command
(88H) at address 5555H in the last byte sequence. To exit
this mode, the Exit Sec ID command should be executed.
Refer to Table 6 for more details.
Product Identification
The Product Identification mode identifies the devices as
the SST39WF1601, SST39WF1602 and manufacturer as
SST. This mode may be accessed software operations.
Users may use the Software Product Identification opera-
tion to identify the part (i.e., using the device ID) when
using multiple manufacturers in the same socket. For
details, see Table 6 for software operation, Figure 12 for
the Software ID Entry and Read timing diagram and Fig-
flowchart.
TABLE 3: Product Identification
Address
Manufacturer’s ID
Device ID
SST39WF1601
SST39WF1602
0001H
0001H
BF274B
BF274A
T3.0 1297
Data
BFH
0000H
©2006 Silicon Storage Technology, Inc.