SMS66  
Preliminary Information  
VDD (+2.7V to +5.5V)  
or 12VIN ( +8V to +15V)  
2.7V  
2.5V  
2.0V  
1.8V  
1.5V  
tDPOND  
tDPONB  
RST#  
tDPONE  
tDPONF  
tDPONA  
tDPONC  
tPRTO  
Figure 2 – Example Power Supply Sequencing and System Start-up Initialization using the SMS66.  
Any order of supply sequencing can be applied using the SMS66 with very accurate monitoring and  
supervisory functions.  
GENERAL DESCRIPTION  
The SMS66 is a highly integrated power supply  
controller, monitor and sequencer. It has the ability to  
control, monitor and sequence up to six power  
supplies. Also, the SMS66 can monitor the VDD input,  
the 12V input, two general-purpose analog inputs and  
the internal temperature sensor. The SMS66 has  
three operating modes: Power-on sequencing mode,  
monitor mode, and Power-off sequencing mode.  
The 10-bit ADC cycles through all 11 channels every  
2ms and checks the conversions against the  
programmed threshold limits. The results can be used  
to trigger RST, HEALTHY and FAULT outputs as well  
as to trigger a Power-off or a Force Shutdown  
operation.  
The Power-off sequencing mode can only be entered  
while the SMS66 is in the monitoring mode. It can be  
initiated by either bringing the PWR_ON/OFF pin  
inactive, through I2C control or triggered by a channel  
exceeding its programmed thresholds. Once Power-  
off is initiated it will disable the Active DC Control and  
sequence the PUP outputs off in either the same or  
reverse order as Power-on sequencing and monitor  
the supply voltages to ensure cascading of the  
supplies as they turn off. The sequence termination  
timer can be programmed to immediately disable all  
channels if the Power-off sequencing stalls. The RST  
output will remain active throughout this mode while  
the HEALTHY output remains inactive.  
Power-on sequencing can be initiated via the  
PWR_ON/OFF pin or I2C control. In this mode, the  
SMS66 will sequence the power supply channels on in  
any order by activating the PUP outputs and  
monitoring the respective converter voltages to ensure  
cascading of the supplies. A programmable sequence  
termination timer can be set to disable all channels if  
the Power-on sequence stalls. During this mode the  
HEALTHY output will remain inactive and the RST  
output will remain active.  
Once the Power-on sequencing mode is complete, the  
SMS66 enters monitor mode. In the monitor mode the  
SMS66 supervises the supplies to within 5mV, and  
enables the triggering of outputs by monitored fault  
conditions.  