欢迎访问ic37.com |
会员登录 免费注册
发布采购

SMS66FR15 参数 Datasheet PDF下载

SMS66FR15图片预览
型号: SMS66FR15
PDF下载: 下载PDF文件 查看货源
内容描述: 六通道电源监控和Cacsade序控制器 [Six-Channel Power Supply Supervisor and Cacsade Sequence Controller]
分类和应用: 监控控制器
文件页数/大小: 26 页 / 1051 K
品牌: SUMMIT [ SUMMIT MICROELECTRONICS, INC. ]
 浏览型号SMS66FR15的Datasheet PDF文件第1页浏览型号SMS66FR15的Datasheet PDF文件第2页浏览型号SMS66FR15的Datasheet PDF文件第3页浏览型号SMS66FR15的Datasheet PDF文件第5页浏览型号SMS66FR15的Datasheet PDF文件第6页浏览型号SMS66FR15的Datasheet PDF文件第7页浏览型号SMS66FR15的Datasheet PDF文件第8页浏览型号SMS66FR15的Datasheet PDF文件第9页  
SMS66  
Preliminary Information  
PIN DESCRIPTIONS  
Pin  
Pin  
Pin Name  
Pin Description  
Number Type  
1
I2C Bi-directional data line  
I2C Clock line  
DATA  
SDA  
SCL  
2
CLK  
The address pin is biased either to VDD_CAP or GND.  
When  
3
4
IN  
IN  
A2  
communicating with the SMS66 over the 2-wire bus A2 provides a  
mechanism for assigning a unique bus address.  
Programmable active high/low input. When asserted the RST output will be  
go active. When de-asserted the RST output will go inactive immediately  
after a reset timeout period (tPRTO) if there are no RST trigger sources active.  
This timeout period makes it suitable to use a pushbutton for manual reset.  
MR  
Programmable active high/low input signals the start of the power  
sequencing. When asserted the part will sequence the supplies on and  
when de-asserted the part will sequence the supplies off.  
5
6
7
IN  
IN  
PWR_ON/OFF  
FS  
Programmable active high/low input. Force shutdown is used to immediately  
turn off all converter enable signals (PUP outputs)  
Programmable active high/low open drain Fault output. Active when a  
programmed fault condition exists on AIN1, AIN2, or the internal temperature  
sensor.  
OUT  
FAULT  
Programmable active high/low open drain Healthy output. Active when all  
programmed power supply inputs and monitored inputs are within OV and  
UV limits.  
Programmable active high/low open drain Reset output. Active when a  
programmed fault condition exists on any power supply inputs or monitored  
inputs or when MR is active. RST has a programmable timeout period with  
options for 0.64ms, 25ms, 100ms and 200ms.  
8
9
OUT  
OUT  
HEALTHY  
RST  
10  
11  
General purpose monitored analog input  
General purpose monitored analog input  
IN  
IN  
AIN1  
AIN2  
12, 44,  
39, 34,  
29, 24,  
19  
Ground  
GND  
GND  
Voltage reference input used for A/D conversion where:  
(4XVREF_ADC) = Full Scale for VMA-F and VDD  
(12XVREF_ADC) = FS for 12VIN  
13  
IN  
VREF_ADC  
(2XVREF_ADC) = FS for AIN1 and AIN2.  
VREF_ADC can be connected to VREF_CNTL in most applications.  
14  
Voltage reference output for the internal 1.25V reference.  
O
VREF_OUT  
VMX  
41,36,  
31,26,  
21,16  
Monitored voltage input, VMA through VMF  
IN  
Summit Microelectronics, Inc  
2070 1.0 7/16/03  
4