欢迎访问ic37.com |
会员登录 免费注册
发布采购

BQ60120HEB30NRS 参数 Datasheet PDF下载

BQ60120HEB30NRS图片预览
型号: BQ60120HEB30NRS
PDF下载: 下载PDF文件 查看货源
内容描述: 半砖DC / DC转换器 [Half-brick DC/DC Converter]
分类和应用: 转换器
文件页数/大小: 13 页 / 606 K
品牌: SYNQOR [ SYNQOR WORLDWIDE HEADQUARTERS ]
 浏览型号BQ60120HEB30NRS的Datasheet PDF文件第1页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第2页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第3页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第4页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第6页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第7页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第8页浏览型号BQ60120HEB30NRS的Datasheet PDF文件第9页  
Technical Specification
ELECTRICAL CHARACTERISTICS (Continued)
Parameter
P
FEATURE CHARACTERISTICS
Input:
Output:
Current:
Package:
35-75 V
12 V
30 A
Half-brick
Min.
270
135
-2
3.5
2.7
-2
4.5
-50
113
Typ.
300
150
Max.
330
165
0.8
18
18
0.8
Units
kHz
kHz
V
V
V
V
V
kΩ
%
%
°C
°C
Notes & Conditions
Synchronous to regulation stage
Switching Frequency Regulation Stage
Switching Frequency Isolation Stage
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
ON/OFF Control (Either Option)
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
Load Current Scale Factor
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
5
10
118
120
10
600
1.9
1.4
6
+5
123
Figure A
Measured across Pins 9 & 5; Figure B
Over full temp range; % of nominal Vout
Average PCB Temperature
See App Note: Output Load Current Calc.
RELIABILITY CHARACTERISTICS
10
6
Hrs.
TR-NWT-000332; 80% load,300LFM, 40oC Ta
10
6
Hrs.
MIL-HDBK-217F; 80% load, 300LFM, 40oC Ta
10
6
Hrs. See our website for details
STANDARDS COMPLIANCE
Parameter
P
STANDARDS COMPLIANCE
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
UL/cUL 60950-1
EN60950-1
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter
P
QUALIFICATION TESTING
# Units
32
5
5
10
5
5
5
15 pins
Test Conditions
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
95% rated V
in
and load, units at derating point, 1000 hours
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
T
operating
= min to max, V
in
= min to max, full load, 100 cycles
T
min
-10°C to T
max
+10°C, 5°C steps, V
in
= min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact factory for official product family qualification document.
OPTIONS
SynQor provides various options for Logic Sense, Pin Length and
Feature Set for this family of DC/DC converters. Please consult the
options.
Product # BQ60120HEA30
Phone 1-888-567-9596
PATENTS
SynQor is protected under various patents, including but not lim-
ited to U.S. Patent # 5,999,417; 6,222,742 B1; 6,594,159
B2; 6,545,890 B2.
Doc.# 005-2BH612M Rev. B
09/02/05
Page 5