MQFL-28VE-06S
6V
Output:
Current:
17A
Technical Specification
CONSTRUCTION AND ENVIRONMENTAL STRESS SCREENING OPTIONS
ES-Gꢂade
(-55 ºC to +125 ºC)
(Element Evaluation)
HB-Gꢂade
(-55 ºC to +125 ºC)
(Element Evaluation)
Consistent with
MIL-SꢁD-883F
C-Gꢂade
(-40 ºC to +100 ºC)
Scꢂeening
Inteꢂnal Visual
Yes
ꢀo
Yes
Yes
*
Condition B
(-55 ºC to +125 ºC)
Condition C
(-65 ºC to +150 ºC)
ꢁempeꢂatuꢂe Cycle
Method 1010
Constant
Acceleꢂation
Method 2001
(Y1 Diꢂection)
Condition A
(5000g)
ꢀo
500g
Method 1015
Load Cycled
Buꢂn-in
• 10s period
24 Hꢂs @ +125 ºC
96 Hꢂs @ +125 ºC
160 Hꢂs @ +125 ºC
• 2s @ 100% Load
• 8s @ 0% Load
Method 5005
(Gꢂoup A)
Final Electꢂical ꢁest
+25 ºC
-45, +25, +100 ºC
Full QoꢂSeal
-55, +25, +125 ºC
Full QoꢂSeal
Mechanical Seal,
ꢁheꢂmal, and Coating
Pꢂocess
Full QoꢂSeal
Exteꢂnal Visual
2009
Yes
Yes
*
Constꢂuction Pꢂocess
QoꢂSeal
QoꢂSeal
QoꢂSeal
* Peꢂ IPC-A-610 (rev. D) Class 3
MilQor converters and filters are offered in four variations of construction technique and environmental stress screening options. The
three highest grades, C, ES, and HB, all use SynQor’s proprietary QorSeal™ Hi-Rel assembly process that includes a Parylene-C coating
of the circuit, a high performance thermal compound filler, and a nickel barrier gold plated aluminum case. Each successively higher
grade has more stringent mechanical and electrical testing, as well as a longer burn-in cycle. The ES- and HB-Grades are also con-
structed of components that have been procured through an element evaluation process that pre-qualifies each new batch of devices.
Product # MQFL-28VE-06S
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005209 Rev. 1
04/22/09