欢迎访问ic37.com |
会员登录 免费注册
发布采购

CC2511F8RSP 参数 Datasheet PDF下载

CC2511F8RSP图片预览
型号: CC2511F8RSP
PDF下载: 下载PDF文件 查看货源
内容描述: 低功耗的SoC (系统级芯片)与MCU,存储器, 2.4 GHz射频收发器和USB控制器 [Low-Power SoC (System-on-Chip) with MCU, Memory, 2.4 GHz RF Transceiver, and USB Controller]
分类和应用: 存储电信集成电路射频控制器
文件页数/大小: 244 页 / 2899 K
品牌: TAOS [ TEXAS ADVANCED OPTOELECTRONIC SOLUTIONS ]
 浏览型号CC2511F8RSP的Datasheet PDF文件第126页浏览型号CC2511F8RSP的Datasheet PDF文件第127页浏览型号CC2511F8RSP的Datasheet PDF文件第128页浏览型号CC2511F8RSP的Datasheet PDF文件第129页浏览型号CC2511F8RSP的Datasheet PDF文件第131页浏览型号CC2511F8RSP的Datasheet PDF文件第132页浏览型号CC2511F8RSP的Datasheet PDF文件第133页浏览型号CC2511F8RSP的Datasheet PDF文件第134页  
C2510Fx / CC2511Fx  
0xFF  
0x00  
OVFIF = 1  
OVFIF = 1  
Figure 34: Free-running Mode  
13.9.2.2 Modulo Mode  
IRCON.TxIF flag is only asserted if the  
corresponding interrupt mask bit  
In modulo mode the counter starts from 0x00  
and increments at each active clock edge.  
When the counter value matches the terminal  
count value TxCC0, the counter is loaded with  
0x00 and continues incrementing its value as  
shown in Figure 35. When TxCC0 is reached,  
the TIMIF.TxOVFIF flag is set. The  
TxCTL.OVFIM is set. An interrupt request is  
generated when both TxCTL.OVFIM and  
IEN1.TxENare set to 1. Modulo mode can be  
used for applications where a period other  
than 0xFF is required.  
TxCC0  
0x00  
OVFIF = 1  
OVFIF = 1  
Figure 35: Modulo Mode  
13.9.2.3 Down Mode  
IRCON.TxIF  
corresponding  
is only asserted if the  
interrupt mask bit  
In down mode, after the timer has been  
started, the counter is loaded with the contents  
in TxCC0. The counter then counts down to  
0x00 (terminal count value) and remains at  
0x00 as shown in Figure 36. The flag  
TIMIF.TxOVFIFis set when 0x00 is reached.  
TxCTL.OVFIM is set. An interrupt request is  
generated when both TxCTL.OVFIM and  
IEN1.TxEN are set to 1. The timer down  
mode can generally be used in applications  
where an event timeout interval is required.  
TxCC0  
0x00  
OVFIF = 1  
Figure 36: Down Mode  
13.9.2.4 Up/Down Mode  
When the counter value matches the terminal  
count value TxCC0, the counter counts down  
until 0x00 is reached and it starts counting up  
In up/down mode the counter starts from 0x00  
and increments at each active clock edge.  
SWRS055D  