C2510Fx / CC2511Fx  
AIN6 - AIN7 inputs (AIN6 must have the  
highest input voltage). It is possible to select  
the reference voltage as the input to the ADC  
in order to perform a conversion of the  
reference voltage e.g. for calibration purposes.  
Similarly, it is possible to select the ground  
terminal GND as an input.  
used and CLKCON.CLKSPD should be 000.  
The ADC runs on a clock which is the system  
clock divided by 6 to give a 4.33/4 MHz ADC  
clock. Both the delta-sigma modulator and the  
decimation filter use the ADC clock for their  
calculations. Using other frequencies will affect  
the results, and conversion time. All data  
presented within this data sheet assume the  
use of the high speed crystal oscillator.  
Note: P0_6 and P0_7 do not exist on  
CC2511Fx, hence it is not possible to use  
external voltage reference for the ADC on  
the CC2511Fx.  
The time required to perform a conversion  
depends on the selected decimation rate.  
When, for instance, the decimation rate is set  
to 128, the decimation filter uses exactly 128  
ADC clock periods to calculate the result.  
When a conversion is started, the input  
multiplexer is allowed 16 ADC clock periods to  
settle in case the channel has been changed  
since the previous conversion. The 16 clock  
cycles settling time applies to all decimation  
rates. This means that the conversion time,  
13.10.2.6 ADC Conversion Results  
The digital conversion result is represented in  
two's complement form. For single ended  
configurations the result is always positive (the  
result is the difference between ground and the  
input signal AINn, where n is 0, 1, 2, …, 7) and  
will be a value between 0 and 2047. The  
maximum value is reached when the input  
amplitude is equal VREF, the selected voltage  
reference. For differential configurations the  
difference between two pin pairs are converted  
and this difference can be negatively signed.  
For 12-bit resolution the digital conversion  
result is 2047 when the analog input is equal to  
VREF, and the conversion result is -2048  
when the analog input is equal to -VREF.  
T
conv, is given by:  
Tconv = (decimation rate + 16) x T where  
0.22 µs T 0.23 µs for CC2510Fx, depending  
on the frequency of the high speed crystal  
oscillator  
T = 0.25 µs for CC2511Fx  
13.10.2.8 ADC Interrupts  
The ADC will only generate an interrupt when  
an extra conversion has completed.  
The digital conversion result is available in  
ADCHand ADCLwhen ADCCON1.EOC is set to  
1. Note that the conversion result always  
resides in MSB section of ADCH:ADCL.  
13.10.2.9 ADC DMA Triggers  
DMA triggers 20 – 28 are associated with  
When reading the ADCCON2.SCH bits, the  
number returned will indicate what the last  
conversion was. Notice that when the value  
written to ADCCON2.SCHis less than 1100, the  
number returned will be the number written +  
single-ended  
or  
differential  
conversion  
sequences (ADCCON2.SCH 1100). The ADC  
will generate a DMA trigger event when a new  
sample is ready from a conversion in the  
sequence. The same is the case if a single  
1.  
For example, after a sequence of  
conversion is completed (ADCCON2.SCH  
conversions from AIN0 to AIN4 has completed,  
ADCCON2.SCH will be read as 0101, while  
after a single conversion of the temperature  
sensor has completed, the register field will be  
read as 1110 (same as the value written to it).  
If an extra conversion has been initiated by  
writing to ADCCON3.ECH, ADCCON2.SCH will  
be updated, after the conversion has  
completed, with the same value as written to  
ADCCON3.ECH, even if this value was less  
than 1100.  
1100). Be aware that DMA trigger number 27  
and 28 are shared with the I2S module.  
In addition there is one DMA trigger,  
ADC_CHALL, which is active when new data  
is ready from any of the conversions in the  
ADC conversion sequence and from the single  
conversion defined by ADCCON2.SCH.  
A
completion of an extra conversion will not  
generate a trigger event.  
The DMA triggers are listed in Table 51 on  
Page 105.  
13.10.2.7 ADC Conversion Timing  
The high speed crystal oscillator should be  
selected as system clock when the ADC is  
SWRS055D  