TSL2014
896
y
1 LINEAR SENSOR ARRAY
TAOS040B
−
MAY 2007
Absolute Maximum Ratings
†
Supply voltage range, V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to 6 V
Input voltage range, V
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to V
DD
+ 0.3V
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−20
mA to 20 mA
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Voltage range applied to any output in the high impedance or
power-off state, V
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to V
DD
+ 0.3V
Continuous output current, I
O
(V
O
= 0 to V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Continuous current through V
DD
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−150
mA to 150 mA
Analog output current range, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25°C
to 85°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25°C
to 85°C
Lead temperature on solder pads for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
ESD tolerance, human body model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 V
†
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Recommended Operating Conditions (see Figure 1 and Figure 2)
MIN
Supply voltage, V
DD
Input voltage, V
I
High-level input voltage, V
IH
Low-level input voltage, V
IL
Wavelength of light source,
λ
Clock frequency, f
clock
Sensor integration time, serial t
int
Sensor integration time, parallel t
int
Operating free-air temperature, T
A
Load resistance, R
L
Load capacitance, C
L
4.5
0
2
0
400
5
0.1792
0.090
0
300
NOM
5
MAX
5.5
V
DD
V
DD
0.8
1000
5000
100
100
70
4700
330
UNIT
V
V
V
V
nm
kHz
ms
ms
°C
Ω
pF
The
LUMENOLOGY
r
Company
r
r
Copyright
E
2007, TAOS Inc.
www.taosinc.com
3