DG183/184/185
Specifications
a
for DG185
Test Conditions
Unless Otherwise Specified
A Suffix
–55 to 125_C
B Suffix
–25 to 85_C
Parameter
Analog Switch
Analog Signal Range
e
Drain-Source
On-Resistance
Symbol
V+
V = 15 V, V– = –15 V, V
L
= 5 V
VV
15 V
V
R
= 0 V, V
IN
= 0.8 V or 2 V
f
Temp
b
Typ
c
Min
d
Max
d
Min
d
Max
d
Unit
V
ANALOG
r
DS(on)
I
S
= –10 mA, V
D
= –7.5 V
V
S
=
"10
V, V
D
=
#10
V
V+ = 10 V, V– = –20 V
I
S(off)
V
S
=
"10
V, V
D
=
#10
V
V
S
=
"10
V, V
D
=
#10
V
V+ = 10 V, V– = –20 V
I
D(off)
V
S
=
"10
V, V
D
=
#10
V
I
D(on)
V
D
= V
S
=
"10
V
Full
Room
Full
Room
Hot
Room
Hot
Room
Hot
Room
Hot
Room
Hot
35
0.05
0.07
0.4
0.3
–0.03
–10
15
75
150
1
100
1
100
1
100
1
100
–10
15
100
150
5
100
5
100
5
100
5
100
V
W
Source Off
Leakage C
L k
Current
nA
Drain Off
Leakage C
L k
Current
Channel On
Leakage Current
–2
–200
–10
–200
Digital Input
Input Current with
Input Voltage High
Input Current with
Input Voltage Low
I
INH
I
INL
V
IN
= 5 V
V
IN
= 0 V
Room
Hot
Full
<0.01
10
20
–250
–250
10
20
mA
–30
Dynamic Characteristics
Turn-On Time
Turn-Off Time
Source-Off Capacitance
Drain-Off Capacitance
Channel-On Capacitance
Off Isolation
t
on
t
off
C
S(off)
C
D(off)
C
D(on)
OIRR
f = 1 MHz
V
S
= –5 V, I
D
= 0
V
D
= –5 V, I
S
= 0
V
D
= V
S
= 0 V
f = 1 MHz, R
L
= 75
W
Room
See Switching Time Test Circuit
Room
Room
Room
Room
Room
100
9
6
14
>50
dB
pF
130
150
120
250
300
ns
Power Supplies
Positive Supply Current
Negative Supply Current
Logic Supply Current
Reference Supply Cur-
rent
I+
I–
I
L
I
R
V
IN
= 0 V, or 5 V
Room
Room
Room
Room
0.6
–2.7
3.1
–1
–2
–5.5
4.5
–2
3
–5.5
4.5
mA
3
Notes:
a. Refer to PROCESS OPTION FLOWCHART .
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
Siliconix
S-52895—Rev. D, 16-Jun-97
5