 浏览型号71M6532F-IGT/F的Datasheet PDF文件第51页浏览型号71M6532F-IGT/F的Datasheet PDF文件第52页浏览型号71M6532F-IGT/F的Datasheet PDF文件第53页浏览型号71M6532F-IGT/F的Datasheet PDF文件第54页浏览型号71M6532F-IGT/F的Datasheet PDF文件第56页浏览型号71M6532F-IGT/F的Datasheet PDF文件第57页浏览型号71M6532F-IGT/F的Datasheet PDF文件第58页浏览型号71M6532F-IGT/F的Datasheet PDF文件第59页  
FDS 6531/6532 005  
Data Sheet 71M6531D/F-71M6532D/F  
When system power is not available (i.e. when V1<VBIAS), the 71M6531 will be in one of three battery  
modes: BROWNOUT, LCD, or SLEEP mode. Figure 21 shows a state diagram of the various operation  
modes, with the possible transitions between modes. For information on the timing of mode transitions  
refer to Figure 22 through Figure 24.  
RESET  
MISSION  
V3P3SYS  
falls  
V1 > VBIAS  
V1 <= VBIAS  
IE_PLLRISE  
-> 1  
IE_PLLFALL  
-> 1  
V3P3SYS  
rises  
V3P3SYS  
rises  
LCD_ONLY  
BROWNOUT  
V3P3SYS  
rises  
RESET &  
VBAT_OK  
IE_PB -> 1  
IE_WAKE ->  
1
PB  
SLEEP or  
VBAT_OK  
timer  
LCD  
timer  
PB  
VBAT_OK  
VBAT_OK  
RESET &  
VBAT_OK  
SLEEP  
Figure 21: Operation Modes State Diagram  
When V1 falls below VBIAS or the part wakes up under battery power, the part will automatically enter  
BROWNOUT mode (see Section 2.5 Wake-Up Behavior). From BROWNOUT mode, the part may enter  
either LCD mode or SLEEP mode, as controlled by the MPU via the I/O RAM bits LCD_ONLY and SLEEP.  
The transition from MISSION mode to BROWNOUT mode is signaled by the IE_PLLFALL interrupt flag  
(SFR 0xE8[7]). The transition in the other direction is signaled by the IE_PLLRISE interrupt flag (SFR  
0xE8[6]), when the PLL becomes stable.  
Meters that do not require functionality in the battery modes, e.g. meters that only use the SLEEP  
mode to maintain the RTC, still need to contain code that brings the chip from BROWNOUT  
mode to SLEEP mode. Otherwise, the chip remains in BROWNOUT mode, once the system  
power is missing, and consumes more current than intended.  
Similarly, meters equipped with batteries need to contain code that transitions the chip to SLEEP  
mode as soon as the battery is attached in production. Otherwise, remaining in BROWNOUT  
mode would add unnecessary drain to the battery.  
Transitions from both LCD and SLEEP mode are initiated by wake-up timer timeout conditions or push-  
button events. When the PB pin is pulled high (pushbutton is pressed), the IE_PB interrupt flag (SFR  
0xE8[4]) is set, and when the wake-up timer times out, the IE_WAKE interrupt flag (SFR 0xE8[5]) is set.  
v1.2  
© 2005-2009 TERIDIAN Semiconductor Corporation  
55