欢迎访问ic37.com |
会员登录 免费注册
发布采购

VCO600A622.080MHZ 参数 Datasheet PDF下载

VCO600A622.080MHZ图片预览
型号: VCO600A622.080MHZ
PDF下载: 下载PDF文件 查看货源
内容描述: 压控振荡器锯 [Voltage Controlled Saw Oscillator]
分类和应用: 振荡器压控振荡器
文件页数/大小: 6 页 / 118 K
品牌: VECTRON [ Vectron International, Inc ]
 浏览型号VCO600A622.080MHZ的Datasheet PDF文件第1页浏览型号VCO600A622.080MHZ的Datasheet PDF文件第3页浏览型号VCO600A622.080MHZ的Datasheet PDF文件第4页浏览型号VCO600A622.080MHZ的Datasheet PDF文件第5页浏览型号VCO600A622.080MHZ的Datasheet PDF文件第6页  
VCO-600A Voltage Controlled SAW Oscillator
Pin Information
Table 1. Pin Function
Pin
Symbol
2,12,27
4
5,6,7,8
10
17
19
21
23
25
1,3,9,11,13,14,15,
16,18,20,22,24,26,28
V
CC
CLKIN
1
NC
V
EE
V
BW 2
V
C
OD
3
CLKOUT
CLKOUT
GND
Function
Positive Supply
Test Clock In
No Connect
Negative Supply
Modulation Bandwidth
Adjust
Control Voltage
Output Disable
ECL Output
Complementary
ECLOutput
Case and Circuit
Ground
Top View of Package
1. By setting OD low, a test signal may be applied at CLKIN and fed through the VCO-600A to both the CLKOUT and CLKOUT to facilitate on board
testing. The test signal input applied at CLKIN may be either an ECL or sinewave input (up to 1Vpp, AC coupled). CLKIN is biased internally to
VBB (Vcc-1.3V)
2. An optional capacitor to ground can be placed on VBW to reduce the modulation bandwidth for narrow bandwidth phase-lock loop applications. The
modulation bandwidth will be approximately 1/(12000*C)Hz, where C is equal to the capacitance in Farads. If the optional capacitor is not utilized, VBW
becomes a no connect (NC) and the modulation bandwidth will be approximately equal to the nominal device frequency
÷1200.
3. By setting OD low, the outputs are disabled and CLKOUT is held Low while CLKOUT is held High. The threshold for OD is 1.4V above VEE. OD
should not be driven above mid supply and during normal operation, should be left floating (use with an open collector or 3-State gate for interfacing with
standard logic). If the OD feature is used during normal operation, then CLKIN should be tied through 10KΩ to GND to avoid any possibility of chatter on
the CLKOUT outputs.
Performance Characteristics
Table 2. Electrical Performance
Parameter
Center Frequency,
see ordering information
Operating Temperature
Supply Current
Supply Voltage
1
Absolute Pull Range (Vc= -0.5 to -4.5)
Positive Gain Transfer (freq vs Vc) 155.520MHz
Positive Gain Transfer (freq vs Vc) 622.080MHz
Linearity
Frequency Stability, -40 to 85 wrt 25°C
Output Level Low
2
Output Level High
2
Output Rise Time
3
Output Fall Time
3
Spurious Suppression
Data Symmetry
Control Voltage Input Impedance
Control Voltage Modulation Bandwidth
4
Control Voltage Range
Output Current
Storage Temperature
Soldering Temp./Time
Symbol
F
N
T
OP
I
EE
V
EE
APR
K
V
K
V
Lin
F
STAB
V
OL
V
OH
t
R
t
F
SYM
Z
c
BW
V
C
I
OUT
T
S
T
LS
Minimum
155
-40
-4.5
±50
175
60
Typical
25
55
-5
-
350
135
±3
±150
-
-
250
250
-60
49/51
10
500
-
-
-
-
Maximum
1000
+85
70
-5.5
-
700
290
Units
MHz
°C
mA
V
ppm
ppm/V
ppm/V
%
ppm
V
V
pS
pS
dB
%
KΩ
kHz
V
mA
°C
°C/S
-1.95
-0.98
100
100
-50
45
8
-
V
EE
-
-55
-
-1.63
-0.75
400
400
55
12
-
V
CC
20
125
240/10
1. The VCO-600A may be configured for PECL operation. All outputs and inputs including V
C
are referenced to Vcc
2. Output Levels are standard 10K ECL and are fully 100K ECL compatible.
3. Transition times are measured from 20% to 80% of a full 10K ECL level swing.
4. The modulation bandwidth is a function of nominal center frequency and may be adjusted down through the use of an external capacitor on pin 17.
Please see Figure 1 and Figure 2 along with Notes 1, 2 and 3.
Table 3. Typical Single Side-Band Phase Noise (dBc/Hz)
Offset from Carrier
VCO600A 622.080
100 Hz
-50
1 kHz
-80
10 kHz
-110
100 kHz
-130
1 MHz
-145
Vectron International 267 Lowell Rd, Hudson NH 03051-4916
Tel:1-88-VECTRON-1
2
e-mail vectron@vectron.com