VCO-600A Voltage Controlled SAW Oscillator  
622.080MH  
51.840MHz  
Loop Filter  
VCO-600A  
φ and Freq  
622.080MHz  
Detector  
Divide by 12  
Figure 3. Typical Frequency Translation Diagram  
155.52MHz  
155.52MHz  
Loop Filter  
VCO-600A  
φ and Freq  
155.520MHz  
Detector  
Figure 4. Typical Clock Smoothing Diagram  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional operation is not implied at  
these or any other conditions in excess of conditions represented in the operational sections of this data sheet. Exposure to  
absolute maximum ratings for extended periods may adversely affect device reliability.  
Table 4. Absolute Maximum Ratings  
Parameter  
Power Supply  
Symbol  
VEE  
Iout  
Iout  
VC  
Ratings  
-8 to 0  
Unit  
V
mA  
mA  
V
Output Current1  
20  
50  
Output Current2  
Voltage Control Range1  
Voltage Control Range2  
VEE to VCC  
VEE-0.5 to VCC+0.5  
VC  
V
1 Limts beyond which performance can not be guarenteed.  
2 Limits beyond which device life may be impaired.  
Qualification Conformance  
The VCO-600A family has undergone, and passed, the following Mil-Std qualification.  
Table 5. Environmental Compliance  
Parameter  
Conditions  
Mechanical Shock  
Mechanical Vibration  
Solderability  
MIL-STD-883C 2002.3, TEST A  
MIL-STD-883C 2007.1, TEST A  
MIL-STD-883C 2003.5,  
Gross and Fine Leak  
Resistance to Solvents  
MIL-STD-883C, 1014.7, 100% Tested  
MIL-STD-883C 2016  
Handling Precautions  
Although ESD protection circuitrry has been designed into the the VCO-600A, proper precautions should be taken when handling  
and mounting. VI employs a human body model and a charged-device model (CDM) for ESD susceptibility testing and design  
protection evaluation. ESD thresholds are dependent on the circuit parameters used to define the model. Although no industry wide  
standard has been adopted for the CDM, a standard HBM of resistance=1.5Kohms and capacitance = 100pF is widely used and  
therefore can be used for comparison purposes.  
Table 6. ESD Ratings  
Model  
Human Body Model  
Charged Device Model  
Minimum  
1000 V  
1000 V  
Vectron International 267 Lowell Rd, Hudson NH 03051-4916  
Tel:1-88-VECTRON-1  
e-mail vectron@vectron.com  