W79E632A/W79L632A  
Data Pointer Low  
Bit:  
7
6
5
4
3
2
1
0
DPL.7 DPL.6 DPL.5 DPL.4 DPL.3 DPL.2 DPL.1 DPL.0  
Mnemonic: DPL  
Address: 82h  
This is the low byte of the standard 8052 16-bit data pointer.  
Data Pointer High  
Bit:  
7
6
5
4
3
2
1
0
DPH.7 DPH.6 DPH.5 DPH.4 DPH.3 DPH.2 DPH.1 DPH.0  
Mnemonic: DPH  
Address: 83h  
This is the high byte of the standard 8052 16-bit data pointer.  
Power Control  
Bit:  
7
6
5
-
4
-
3
2
1
0
SMOD0  
SM0D  
GF1  
GF0  
PD  
IDL  
Mnemonic: PCON  
Address: 87h  
SMOD : This bit doubles the serial port baud rate in mode 1, 2, and 3 when set to 1.  
SMOD0: Framing Error Detection Enable: When SMOD0 is set to 1, then SCON.7 indicates a Frame  
Error and acts as the FE flag. When SMOD0 is 0, then SCON.7 acts as per the standard  
8052 function.  
GF1-0: These two bits are general purpose user flags.  
PD:  
Setting this bit causes the W79E(L)632 to go into the POWER DOWN mode. In this mode all  
the  
clocks are stopped and program execution is frozen.  
IDL:  
Setting this bit causes the W79E(L)632 to go into the IDLE mode. In this mode the clocks to  
the  
CPU are stopped, so program execution is frozen. But the clock to the serial, timer and  
interrupt blocks is not stopped, and these blocks continue operating.  
Timer Control  
Bit:  
7
6
5
4
3
2
1
0
TF1  
TR1  
TF0  
TR0  
IE1  
IT1  
IE0  
IT0  
Mnemonic: TCON  
Address: 88h  
TF1: Timer 1 overflow flag: This bit is set when Timer 1 overflows. It is cleared automatically when  
the program does a timer 1 interrupt service routine. Software can also set or clear this bit.  
TR1: Timer 1 run control: This bit is set or cleared by software to turn timer/counter on or off.  
TF0: Timer 0 overflow flag: This bit is set when Timer 0 overflows. It is cleared automatically when  
the program does a timer 0 interrupt service routine. Software can also set or clear this bit.  
- 10 -