1~4 Output Medical Type
Output Chart
MODEL
MPS-120-3.3
MPS-120-5
MPS-120-12
MPS-120-15
MPS-120-24
MPS-120-48
MPD-120A
OUTPUT
VOLTAGE
3.3V
5V
12V
15V
24V
48V
5V
12V
MPD-120B
5V
24V
MPT-120A
5V
12V
-5V
MPT-120B
5V
12V
-12V
MPT-120C
5V
15V
-15V
MPT-120D
5V
24V
12V
MPQ-120B
5V
12V
-5V
-12V
MPQ-120C
5V
15V
-5V
-15V
MPQ-120D
5V
12V
24V
-12V
MPQ-120E
5V
12V
15V
24V
Notes :
120W Medical
WITH FAN
(25CFM)
24A
22A
10A
8A
5A
2.5A
10A
5A
10A
2.9A
10A
4.8A
0.6A
10A
4.4A
0.6A
10A
4A
0.6A
10A
2.2A
0.6A
10A
4.2A
0.6A
0.6A
10A
3.2A
0.6A
0.6A
10A
1A
2.1A
0.6A
10A
3A
0.6A
0.6A
RIPPLE & NOISE VOLTAGE
PEAK LOAD (Max.)
TOLERANCE
WITH 25CFM FAN
(Note 2)
(Note 3)
26A
26A
11A
8.8A
5.5A
2.8A
12A
6A
12A
3.2A
12A
5.8A
1A
12A
5.3A
1A
11A
4.4A
1A
12A
2.64A
1A
11A
5A
1A
1A
11A
3.8A
1A
1A
11A
1.1A
2.3A
1A
11A
3.3A
1A
1A
80mVp-p
80mVp-p
100mVp-p
100mVp-p
120mVp-p
120mVp-p
80mVp-p
120mVp-p
80mVp-p
250mVp-p
80mVp-p
120mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
80mVp-p
150mVp-p
80mVp-p
80mVp-p
300mVp-p
120mVp-p
80mVp-p
120mVp-p
80mVp-p
80mVp-p
80mVp-p
150mVp-p
80mVp-p
80mVp-p
80mVp-p
150mVp-p
300mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
80mVp-p
3.0%
3.0%
2.0%
2.0%
2.0%
2.0%
2.0%
7.0%
2.0%
8.0%
2.0%
+8,-6%
5.0%
2.0%
6.0%
5.0%
2.0%
+6,-7%
5.0%
2.0%
+8,-6%
5.0%
2.0%
6.0%
5.0%
5.0%
2.0%
+6,-7%
5.0%
5.0%
2.0%
+8,-6%
8.0%
5.0%
2.0%
6.0%
8.0%
5.0%
series
RATED
CURRENT
24A
22A
10A
8A
5A
2.5A
10A
5A
10A
2.9A
10A
4.8A
0.6A
10A
4.4A
0.6A
10A
4A
0.6A
10A
2.2A
0.6A
10A
4.2A
0.6A
0.6A
10A
3.2A
0.6A
0.6A
10A
1A
2.1A
0.6A
10A
3A
0.6A
0.6A
OUTPUT CURRENT
MINIMUM
LOAD
0A
0A
0A
0A
0A
0A
2A
0.5A
2A
0.3A
2A
0.4A
0A
2A
0.4A
0A
2A
0.4A
0A
2A
0.4A
0A
2A
0.5A
0A
0A
2A
0.5A
0A
0A
2A
0.2A
0.3A
0A
2A
0.5A
0A
0A
CONVECTION
(max.)
16A
14.7A
6.7A
5.3A
3.3A
1.7A
7.3A
3.6A
7A
1.9A
7.3A
3.5A
0.3A
7.3A
3.2A
0.4A
7A
2.6A
0.4A
7.3A
1.6A
0.4A
7.3A
3.1A
0.4A
0.4A
7.3A
2.4A
0.4A
0.4A
7A
0.7A
1.4A
0.3A
7.3A
2.3A
0.4A
0.4A
LINE
LOAD
REGULATION REGULATION EFFICIENCY
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
2.0%
0.5%
2.0%
0.5%
1.5%
0.5%
0.5%
1.5%
0.5%
0.5%
2.0%
0.5%
0.5%
3.0%
0.5%
0.5%
1.5%
0.5%
0.5%
0.5%
2.0%
0.5%
0.5%
0.5%
2.0%
2.0%
0.5%
0.5%
2.0%
2.0%
0.5%
3.0%
3.0%
2.0%
2.0%
2.0%
2.0%
0.5%
3.5%
0.5%
4.0%
1.0%
3.5%
1.0%
1.0%
3.5%
1.0%
1.0%
3.5%
1.0%
1.0%
+4,-3%
1.0%
0.5%
3.5%
1.0%
1.0%
0.5%
3.5%
1.0%
1.0%
0.5%
3.5%
3.5%
1.0%
0.5%
3.0%
3.0%
1.0%
73%
74%
71%
71%
74%
72%
73%
72%
68%
73%
77%
79%
81%
82%
75%
(Note 4)
76%
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:120W MEDICAL-SPEC 2006-04-13