欢迎访问ic37.com |
会员登录 免费注册
发布采购

ZL50404 参数 Datasheet PDF下载

ZL50404图片预览
型号: ZL50404
PDF下载: 下载PDF文件 查看货源
内容描述: 轻轻托管/非托管5端口10 / 100M以太网交换机 [Lightly Managed/Unmanaged 5-Port 10/100M Ethernet Switch]
分类和应用: 以太网局域网(LAN)标准
文件页数/大小: 121 页 / 1386 K
品牌: ZARLINK [ ZARLINK SEMICONDUCTOR INC ]
 浏览型号ZL50404的Datasheet PDF文件第80页浏览型号ZL50404的Datasheet PDF文件第81页浏览型号ZL50404的Datasheet PDF文件第82页浏览型号ZL50404的Datasheet PDF文件第83页浏览型号ZL50404的Datasheet PDF文件第85页浏览型号ZL50404的Datasheet PDF文件第86页浏览型号ZL50404的Datasheet PDF文件第87页浏览型号ZL50404的Datasheet PDF文件第88页  
ZL50404
Data Sheet
Their respective priority can be programmed via Well_Known_Port [7:0] priority register. Well_Known_Port_Enable
can individually turn on/off each Well Known Port if desired.
Similarly, the User Defined Logical Port provides the user programmability to the priority, plus the flexibility to select
specific logical ports to fit the applications. The 8 User Logical Ports can be programmed via User_Port 0-7
registers. Two registers are required to be programmed for the logical port number. The respective priority can be
programmed to the User_Port [7:0] priority register. The port priority can be individually enabled/disabled via
User_Port_Enable register.
The User Defined Range provides a range of logical port numbers with the same priority level. Programming is
similar to the User Defined Logical Port. Instead of programming a fixed port number, an upper and lower limit need
to be programmed, they are: {RHIGHH, RHIGHL} and {RLOWH, RLOWL} respectively. If the value in the upper
limit is smaller or equal to the lower limit, the function is disabled. Any IP packet with a logical port that is less than
the upper limit and more than the lower limit will use the priority specified in RPRIORITY.
13.3.6.22
WELL_KNOWN_PORT[1:0]_PRIORITY- Well Known Logic Port 1 and 0 Priority
I²C Address h0A8, CPU Address 560
Accessed by CPU and I²C (R/W)
Bits[3:0]:
Bits[7:4]:
Priority setting, transmission + dropping, for Well known port 0 (23 for telnet)
Priority setting, transmission + dropping, for Well known port 1 (512 for
TCP/UDP)
13.3.6.23
WELL_KNOWN_PORT[3:2]_PRIORITY- Well Known Logic Port 3 and 2 Priority
I²C Address h0A9, CPU Address 561
Accessed by CPU and I²C (R/W)
Bits[3:0]:
Bits[7:4]:
Priority setting, transmission + dropping, for Well known port 2 (6000 for
XWIN)
Priority setting, transmission + dropping, for Well known port 3 (443 for HTTP
sec)
13.3.6.24
WELL_KNOWN_PORT[5:4]_PRIORITY- Well Known Logic Port 5 and 4 Priority
I²C Address h0AA, CPU Address 562
Accessed by CPU and I²C (R/W)
Bits[3:0]:
Bits[7:4]:
Priority setting, transmission + dropping, for Well known port 4 (111 for sun
remote procedure call)
Priority setting, transmission + dropping, for Well known port 5 (22555 for IP
Phone call setup)
84
Zarlink Semiconductor Inc.