ADG46+1/ADG46+3
Parameter
25°C
−±1
0.85
−40°C to +85°C
Unit
Test Conditions/Comments
Channel-to-Channel Crosstalk
Total Harmonic Distortion + Noise, THD + N
dB typ
% typ
RL = 50 Ω, CL = 5 pF, f = 100 kHz; see Figure 29
RL = 110 Ω, f = 20 Hz to 20 kHz, VS = 3.5 V p-p;
see Figure 31
Insertion Loss
−3 dB Bandwidth
−0.5
293
dB typ
MHz
typ
RL = 50 Ω, CL = 5 pF; f = 1 MHz; see Figure 30
RL = 50 Ω, CL = 5 pF; see Figure 30
CS (Off)
CD (Off)
CD (On), CS (On)
POWER REQUIREMENTS
Normal Mode
IDD
14
14
50
pF typ
pF typ
pF typ
VS = 0 V, f = 1 MHz
VS = 0 V, f = 1 MHz
VS = 0 V, f = 1 MHz
VDD = 5.5 V, VSS = 0 V
Digital inputs = 0 V or VDD
90
μA typ
140
165
165
μA max
Isolation Mode
IDD
VDD = 5.5 V, VSS = 0 V or floating
Digital inputs = 0 V or 5.5 V
90
140
μA typ
μA max VS = 1 V/16 V, VD = 16 V/1 V
1 Guaranteed by design, not subject to production test.
CONTINUOUS CURRENT PER CHANNEL, SX OR DX
Table 4.
Parameter
25°C
85°C
Unit
CONTINUOUS CURRENT, Sx OR Dx
VDD = +5 V, VSS = −5 V
TSSOP (θJA = 112°C/W)
LFCSP (θJA = 48.±°C/W)
VDD = 12 V, VSS = 0 V
TSSOP (θJA = 112°C/W)
LFCSP (θJA = 48.±°C/W)
VDD = 5 V, VSS = 0 V
109
160
52
83
mA maximum
mA maximum
113
1±5
56
8±
mA maximum
mA maximum
TSSOP (θJA = 112°C/W)
LFCSP (θJA = 48.±°C/W)
±8
118
39
56
mA maximum
mA maximum
POWER SUPPLY OPERATION
Temperature range is −40°C to +105°C, unless otherwise noted.
Table 5.
Parameter
POWER SUPPLY
VDD to VSS
VDD
VSS
Min
Max
Unit
Comments
16
16
0
V
V
V
GND = 0 V
GND = 0 V
GND = 0 V
2.±
−5.5
DUAL SUPPLY
VSS/VDD
−5.5
0
+10.5
16
V
V
VDD to VSS = 16 V, GND = 0 V
SINGLE SUPPLY
VDD
Analog Signal Range, VD, VS
Normal Mode
Isolation Mode
VDD to VSS = 16 V, GND = 0 V, VSS = 0 V
VDD to VSS = 16 V maximum
Most negative (VS ,VD, or VSS) to most positive
(VS ,VD, Inx, or VDD) = 16 V maximum
−5.5
−5.5
VDD
+16
V
V
Rev. 0 | Page 8 of 24